Question 1 25% Light crude oil is imported and stored on site in a 10m high bunded tank with a floating roof. The crude oil pump is located in the bunded area. The crude oil is pumped via a pipe at the continuous volumetric flow rate of 1million tonnes per annum to a fractionating column some 50m from the tank. The feed to the column is 20m above ground level. The oil goes through 6 right angle bends and a control valve with 2 block valves in a manifold with a second pump ready to be brought online in the event of a failure. Determine the size of pipe you will need to minimise cost. Design a pump suitable for this task. Consider where this volume sits on a pump curve and determine if more than one pump is required. You can assume the tank is at 25 degrees C and that its density is 0.8tonne/m3. What, if any, operational aspects will occur as the tank is emptied?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
Question 1 25% Light crude oil is imported and stored on site in a 10m high bunded tank with a floating roof. The crude oil pump is located in the bunded area. The crude oil is pumped via a pipe at the continuous volumetric flow rate of 1million tonnes per annum to a fractionating column some 50m from the tank. The feed to the column is 20m above ground level. The oil goes through 6 right angle bends and a control valve with 2 block valves in a manifold with a second pump ready to be brought online in the event of a failure. Determine the size of pipe you will need to minimise cost. Design a pump suitable for this task. Consider where this volume sits on a pump curve and determine if more than one pump is required. You can assume the tank is at 25 degrees C and that its density is 0.8tonne/m3. What, if any, operational aspects will occur as the tank is emptied?
Expert Solution
steps

Step by step

Solved in 2 steps with 6 images

Blurred answer
Similar questions
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The