Q2: Level and Temperature Control of a Tank The figure below shows a sketch of an open tank that is installed in the plant of which liquid level and temperature are to be controlled. Design a typical PLC program for this control process. The sequence of operations for this system is as follow: 1. Master start/stop is also provided to shut down or start the entire process 2. To detect high and low level of liquid in the tank, two level switches are used which gives output in digital terms, that is when corresponding levels are detected, it gives output high otherwise remain low. 3. Inlet valve to control inlet process flow and outlet valve to control outlet process flow. 4. When level reaches the Level Low, Outlet flow is blocked, and inlet flow is allowed until high level is achieved. 5. A temperature sensor (NO) is used for measuring the temperature of the tanks. 6. Heating process is used to heat the material in the tank. 7. The heater is switched on when the tank is full, and the temperature is below the desirable temperature. 8. Outlet valves are used at the bottom of the tanks to drain the materials when the desirable temperature and level high are satisfied. material START STOP LH 1 Heater LL 1 Outlet valve V4 Product A To heat umentationTools.com TT 1 •

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q2: Level and Temperature Control of a Tank
The figure below shows a sketch of an open tank that is installed in the plant of which liquid level and
temperature are to be controlled. Design a typical PLC program for this control process.
The sequence of operations for this system is as follow:
1. Master start/stop is also provided to shut down or start the entire process
2. To detect high and low level of liquid in the tank, two level switches are used which gives
output in digital terms, that is when corresponding levels are detected, it gives output high
otherwise remain low.
3.
Inlet valve to control inlet process flow and outlet valve to control outlet process flow.
4. When level reaches the Level Low, Outlet flow is blocked, and inlet flow is allowed until high
level is achieved.
5.
A temperature sensor (NO) is used for measuring the temperature of the tanks.
6. Heating process is used to heat the material in the tank.
7. The heater is switched on when the tank is full, and the temperature is below the desirable
temperature.
8. Outlet valves are used at the bottom of the tanks to drain the materials when the desirable
temperature and level high are satisfied.
material
LH 1
Heater
LL 1
Outlet valve
V4
Product A
To heat
40₂
umentationTools .com
TT 1
START
STOP
Transcribed Image Text:Q2: Level and Temperature Control of a Tank The figure below shows a sketch of an open tank that is installed in the plant of which liquid level and temperature are to be controlled. Design a typical PLC program for this control process. The sequence of operations for this system is as follow: 1. Master start/stop is also provided to shut down or start the entire process 2. To detect high and low level of liquid in the tank, two level switches are used which gives output in digital terms, that is when corresponding levels are detected, it gives output high otherwise remain low. 3. Inlet valve to control inlet process flow and outlet valve to control outlet process flow. 4. When level reaches the Level Low, Outlet flow is blocked, and inlet flow is allowed until high level is achieved. 5. A temperature sensor (NO) is used for measuring the temperature of the tanks. 6. Heating process is used to heat the material in the tank. 7. The heater is switched on when the tank is full, and the temperature is below the desirable temperature. 8. Outlet valves are used at the bottom of the tanks to drain the materials when the desirable temperature and level high are satisfied. material LH 1 Heater LL 1 Outlet valve V4 Product A To heat 40₂ umentationTools .com TT 1 START STOP
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Mathematical Modeling of Mechanical System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,