Q11 A 600W, 115V, 60Hz capacitor-start motor draws 13.8A from the supply at rated load. If the efficiency is 65% and rated speed is 1750 r.p.m., calculate (i) input power at rated load (ii) power factor at rated load (iii) rated motor horsepower. Ans[ 923.1W, 0.582 lag, 0.8 h.p.)

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter12: Power System Controls
Section: Chapter Questions
Problem 12.4P
icon
Related questions
Question
Solve a
Q11 A 600W, 115V, 60Hz capacitor-start motor draws 13.8A from the supply at rated load. If the
efficiency is 65% and rated speed is 1750 r.p.m., calculate (i) input power at rated load (ii)
power factor at rated load (iii) rated motor horsepower. Ans[ 923.1W, 0.582 lag, 0.8
h.p.)
Transcribed Image Text:Q11 A 600W, 115V, 60Hz capacitor-start motor draws 13.8A from the supply at rated load. If the efficiency is 65% and rated speed is 1750 r.p.m., calculate (i) input power at rated load (ii) power factor at rated load (iii) rated motor horsepower. Ans[ 923.1W, 0.582 lag, 0.8 h.p.)
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Basic Signals and Its Properties
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning