Problem 5.7 For air-conditioning system operation in cold weather, it is possible to introduce enough outdoor air to eliminate cooling by the air conditioner. This is called an economizer, and the control strategy is to vary the amount of outdoor air entering a plenum so that the outlet state is at the set point. For zone conditions of 75 F and 50 % and a constant circulating air flow rate of 25,000 cfm, determine the outdoor and return air flow rates necessary to maintain a 55 F supply air leaving the plenum. The outdoor air temperature varies between 10 F and 50 F and the relative humidity is always 30 %. Draw some conclusions from your results.
Problem 5.7 For air-conditioning system operation in cold weather, it is possible to introduce enough outdoor air to eliminate cooling by the air conditioner. This is called an economizer, and the control strategy is to vary the amount of outdoor air entering a plenum so that the outlet state is at the set point. For zone conditions of 75 F and 50 % and a constant circulating air flow rate of 25,000 cfm, determine the outdoor and return air flow rates necessary to maintain a 55 F supply air leaving the plenum. The outdoor air temperature varies between 10 F and 50 F and the relative humidity is always 30 %. Draw some conclusions from your results.
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
![Problem 5.7 For air-conditioning system operation in cold weather, it is possible to introduce enough outdoor air to eliminate
cooling by the air conditioner. This is called an economizer, and the control strategy is to vary the amount of outdoor air
entering a plenum so that the outlet state is at the set point. For zone conditions of 75 F and 50 % and a constant circulating
air flow rate of 25,000 cfm, determine the outdoor and return air flow rates necessary to maintain a 55 F supply air leaving
the plenum. The outdoor air temperature varies between 10 F and 50 F and the relative humidity is always 30 %. Draw
some conclusions from your results.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Feca5cdb7-b805-4015-9687-0ae13b0f0f8f%2F568a8c81-3e3d-49b4-aacd-14d5e77c0133%2Fckcntc_processed.png&w=3840&q=75)
Transcribed Image Text:Problem 5.7 For air-conditioning system operation in cold weather, it is possible to introduce enough outdoor air to eliminate
cooling by the air conditioner. This is called an economizer, and the control strategy is to vary the amount of outdoor air
entering a plenum so that the outlet state is at the set point. For zone conditions of 75 F and 50 % and a constant circulating
air flow rate of 25,000 cfm, determine the outdoor and return air flow rates necessary to maintain a 55 F supply air leaving
the plenum. The outdoor air temperature varies between 10 F and 50 F and the relative humidity is always 30 %. Draw
some conclusions from your results.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 1 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Elements Of Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780190698614/9780190698614_smallCoverImage.gif)
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
![Mechanics of Materials (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134319650/9780134319650_smallCoverImage.gif)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Thermodynamics: An Engineering Approach](https://www.bartleby.com/isbn_cover_images/9781259822674/9781259822674_smallCoverImage.gif)
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
![Elements Of Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780190698614/9780190698614_smallCoverImage.gif)
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
![Mechanics of Materials (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134319650/9780134319650_smallCoverImage.gif)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Thermodynamics: An Engineering Approach](https://www.bartleby.com/isbn_cover_images/9781259822674/9781259822674_smallCoverImage.gif)
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
![Control Systems Engineering](https://www.bartleby.com/isbn_cover_images/9781118170519/9781118170519_smallCoverImage.gif)
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
![Mechanics of Materials (MindTap Course List)](https://www.bartleby.com/isbn_cover_images/9781337093347/9781337093347_smallCoverImage.gif)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
![Engineering Mechanics: Statics](https://www.bartleby.com/isbn_cover_images/9781118807330/9781118807330_smallCoverImage.gif)
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY