P = 80 - 2 x 10 (a) Determine the valve coefficient C if the required maximum water flow rate is 1.6 times greater than the design flow rate. (b) Consider a control valve with linear trim and equal percentage control valves with R = 20 and R = 50. Compare the three control valves by plotting the installed valve characteristics (q vs. ). Which valve would you recommend and why?

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter19: Special-purpose Outlets-water Pump, Water Heater
Section19.2: Water Heater Branch Circuit
Problem 8R: For residential water heaters, the Consumer Product Safety Commission suggests a maximum temperature...
icon
Related questions
Question
100%

Process Dynamic and Control Question 

3. A circulating cooling water system is used for the coolant in a shell and tube heat exchanger.
The cooling water is first pumped through a refrigerated cooler and then through the heat
exchanger. At the design flow rate of q = 400 gpm, the water pressure drop through the
refrigerated cooler is 10 psi, and the pressure drop through the heat exchanger is 15 psi. The
water pressure drops through the refrigerated cooler and heat exchanger are proportional to
the flow rate squared. The water supply pump discharge pressure in psig is given by the
following equation to overcome losses in the cooler, heat exchanger and control valve:
P = 80 - 2 x 10 -> q 2
(a) Determine the valve coefficient C if the required maximum water flow rate is 1.6 times
greater than the design flow rate.
(b) Consider a control valve with linear trim and equal percentage control valves with R =
20 and R = 50. Compare the three control valves by plotting the installed valve
characteristics (q vs. ). Which valve would you recommend and why?
Transcribed Image Text:3. A circulating cooling water system is used for the coolant in a shell and tube heat exchanger. The cooling water is first pumped through a refrigerated cooler and then through the heat exchanger. At the design flow rate of q = 400 gpm, the water pressure drop through the refrigerated cooler is 10 psi, and the pressure drop through the heat exchanger is 15 psi. The water pressure drops through the refrigerated cooler and heat exchanger are proportional to the flow rate squared. The water supply pump discharge pressure in psig is given by the following equation to overcome losses in the cooler, heat exchanger and control valve: P = 80 - 2 x 10 -> q 2 (a) Determine the valve coefficient C if the required maximum water flow rate is 1.6 times greater than the design flow rate. (b) Consider a control valve with linear trim and equal percentage control valves with R = 20 and R = 50. Compare the three control valves by plotting the installed valve characteristics (q vs. ). Which valve would you recommend and why?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Routh Hurwitz Criteria
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.