original ssD 400x (100) 2 400 x (14)=100 34 10or (2)² = 100 × (0-85) = 100 x = 72.25 100x 40 72.25 =36.13 500 36.13 13.84 O. 7225 12x13.84≈ 166.08mAs 10) The dose of a radiograph was 100 mSv with a technique of: 10 mAs, 180 kV at 200 cm and tabletop. If the technique is changed to: 20 mAs, 153 kV at 100 cm using a 5:1 grid then find the new dose in rem to the Lungs. 11) A radiographic technique produces an exposure index of EI= 300 and TEI=600 at a source- to-image receptor distance (SID) of 200 cm, 100 kV, 5:1 grid using 10 mAs. If the technique is changed to 100 cm and 85 kV and 5 mAs with table top find the new exposure index? What is the value of DI? 10

Advanced Engineering Mathematics
10th Edition
ISBN:9780470458365
Author:Erwin Kreyszig
Publisher:Erwin Kreyszig
Chapter2: Second-order Linear Odes
Section: Chapter Questions
Problem 1RQ
icon
Related questions
Question
original ssD
400x (100) 2 400 x (14)=100
34
10or (2)² = 100 × (0-85) = 100 x = 72.25
100x
40
72.25 =36.13
500
36.13 13.84
O. 7225
12x13.84≈ 166.08mAs
10) The dose of a radiograph was 100 mSv with a technique of: 10 mAs, 180 kV at 200 cm and
tabletop. If the technique is changed to: 20 mAs, 153 kV at 100 cm using a 5:1 grid then find the
new dose in rem to the Lungs.
11) A radiographic technique produces an exposure index of EI= 300 and TEI=600 at a source-
to-image receptor distance (SID) of 200 cm, 100 kV, 5:1 grid using 10 mAs. If the technique is
changed to 100 cm and 85 kV and 5 mAs with table top find the new exposure index? What is
the value of DI?
10
Transcribed Image Text:original ssD 400x (100) 2 400 x (14)=100 34 10or (2)² = 100 × (0-85) = 100 x = 72.25 100x 40 72.25 =36.13 500 36.13 13.84 O. 7225 12x13.84≈ 166.08mAs 10) The dose of a radiograph was 100 mSv with a technique of: 10 mAs, 180 kV at 200 cm and tabletop. If the technique is changed to: 20 mAs, 153 kV at 100 cm using a 5:1 grid then find the new dose in rem to the Lungs. 11) A radiographic technique produces an exposure index of EI= 300 and TEI=600 at a source- to-image receptor distance (SID) of 200 cm, 100 kV, 5:1 grid using 10 mAs. If the technique is changed to 100 cm and 85 kV and 5 mAs with table top find the new exposure index? What is the value of DI? 10
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Advanced Engineering Mathematics
Advanced Engineering Mathematics
Advanced Math
ISBN:
9780470458365
Author:
Erwin Kreyszig
Publisher:
Wiley, John & Sons, Incorporated
Numerical Methods for Engineers
Numerical Methods for Engineers
Advanced Math
ISBN:
9780073397924
Author:
Steven C. Chapra Dr., Raymond P. Canale
Publisher:
McGraw-Hill Education
Introductory Mathematics for Engineering Applicat…
Introductory Mathematics for Engineering Applicat…
Advanced Math
ISBN:
9781118141809
Author:
Nathan Klingbeil
Publisher:
WILEY
Mathematics For Machine Technology
Mathematics For Machine Technology
Advanced Math
ISBN:
9781337798310
Author:
Peterson, John.
Publisher:
Cengage Learning,
Basic Technical Mathematics
Basic Technical Mathematics
Advanced Math
ISBN:
9780134437705
Author:
Washington
Publisher:
PEARSON
Topology
Topology
Advanced Math
ISBN:
9780134689517
Author:
Munkres, James R.
Publisher:
Pearson,