Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced emf, a device user can estimate the patient's breathing rate. Mindy needs the apparatus to be able to detect a change in area as small as 4.50 cm2 occuring over a time period of 1.50 s. If the minimum emf that can be reliably detected is 3.00×10−4 V, what is the magnitude of the minimum external magnetic field that would be needed from the solenoid? magnitude of minimum external magnetic field=???   Due to practical constraints, the largest magnetic field that the solenoid can actually produce is 2.40×10−3 T. Mindy decides to compensate by using multiple loops of the conductive material in series. How many conductive loops should be in the chest band?   minimum number of conductive loops=??

icon
Related questions
Question

Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced emf, a device user can estimate the patient's breathing rate.

Mindy needs the apparatus to be able to detect a change in area as small as 4.50 cm2 occuring over a time period of 1.50 s. If the minimum emf that can be reliably detected is 3.00×10−4 V, what is the magnitude of the minimum external magnetic field that would be needed from the solenoid?

magnitude of minimum external magnetic field=???
 
Due to practical constraints, the largest magnetic field that the solenoid can actually produce is 2.40×10−3 T. Mindy decides to compensate by using multiple loops of the conductive material in series. How many conductive loops should be in the chest band?
 
minimum number of conductive loops=??
 
 
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a
stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external
magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The
resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced emf, a device
user can estimate the patient's breathing rate.
Mindy needs the apparatus to be able to detect a change in area as small as 4.50 cm? occuring over a time period of 1.50 s. If
the minimum emf that can be reliably detected is 3.00 x 10-4 V, what is the magnitude of the minimum external magnetic
field that would be needed from the solenoid?
magnitude of minimum external magnetic field:
1
T
* TOOLS
Due to practical constraints, the largest magnetic 1
x10
ually produce is 2.40 x 10-3 T. Mindy decides
to compensate by using multiple loops of the conductive material in series. How many conductive loops should be in the
chest band?
minimum number of conductive loops:
Transcribed Image Text:Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced emf, a device user can estimate the patient's breathing rate. Mindy needs the apparatus to be able to detect a change in area as small as 4.50 cm? occuring over a time period of 1.50 s. If the minimum emf that can be reliably detected is 3.00 x 10-4 V, what is the magnitude of the minimum external magnetic field that would be needed from the solenoid? magnitude of minimum external magnetic field: 1 T * TOOLS Due to practical constraints, the largest magnetic 1 x10 ually produce is 2.40 x 10-3 T. Mindy decides to compensate by using multiple loops of the conductive material in series. How many conductive loops should be in the chest band? minimum number of conductive loops:
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 7 images

Blurred answer