Milk at 400C with a specific temperature of 3.85 kJ / kg K will be pasteurized at 75 oC using saturated steam at 120 oC in a plate heat exchanger. The heat exchanger operates in parallel current. In heating, the latent heat of the steam is used. What is the steam / milk ratio accordingly? The data required for steam is given in the table below.
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
3- Milk at 400C with a specific temperature of 3.85 kJ / kg K will be pasteurized at 75 oC using saturated steam at 120 oC in a plate heat exchanger. The heat exchanger operates in parallel current. In heating, the latent heat of the steam is used. What is the steam / milk ratio accordingly? The data required for steam is given in the table below.
Enthalpy (MJ / kg) Temperature (oC) Absolute pressure (kPa) Saturated liquid Evaporation Saturated steam
75 38.5575 0.31394 2.3214 2.6354
120 198.54 0.50372 2.20225 2.70607
A. 17,75
B. 56.33
C. 0,056
D. 0,017
E. 68,7
Step by step
Solved in 2 steps with 4 images