me: 16' 5. What is the perimeter in feet of exposed wall for the entire house provided? NOTE 1: The wall height for all rooms is 11 feet. NOTE 2: When calculating heat gain and loss for the provided drawing, Round U factor to 3 decimals places, Round heating transfer multiplier (HTM) to two decimal places. NOTE 3: For each window, door or surface area, round off square feet to the nearest whole number. 2'8 X 4'0 2'8 X 4'0 Answer Room 3: 10' X8' 5'0 X 6'0 Room 4 22' X16' Room 2 18' X14' 5'0 X 6'0 2'8 X 6'8" 3'Q X 6'8" 2 W 3. 2'0 X 3'0 Room 5 26' X20' ID: B Room 1 30' X18' Room 6 8' X8' 5'0 X 6'0 2'8 X 4'0 0.9 X 0.5
me: 16' 5. What is the perimeter in feet of exposed wall for the entire house provided? NOTE 1: The wall height for all rooms is 11 feet. NOTE 2: When calculating heat gain and loss for the provided drawing, Round U factor to 3 decimals places, Round heating transfer multiplier (HTM) to two decimal places. NOTE 3: For each window, door or surface area, round off square feet to the nearest whole number. 2'8 X 4'0 2'8 X 4'0 Answer Room 3: 10' X8' 5'0 X 6'0 Room 4 22' X16' Room 2 18' X14' 5'0 X 6'0 2'8 X 6'8" 3'Q X 6'8" 2 W 3. 2'0 X 3'0 Room 5 26' X20' ID: B Room 1 30' X18' Room 6 8' X8' 5'0 X 6'0 2'8 X 4'0 0.9 X 0.5
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
![### Calculating the Perimeter of Exposed Wall for a House
**Problem Statement:**
What is the perimeter in feet of the exposed wall for the entire house provided?
**Guidelines:**
1. **Wall Height for All Rooms:**
- The height is 11 feet.
2. **Heat Gain and Loss Calculation:**
- For the provided drawing, round the U factor to 3 decimal places.
- Round the Heating Transfer Multiplier (HTM) to two decimal places.
3. **Rounding Off:**
- For each window, door, or surface area, round off square feet to the nearest whole number.
**Room Dimensions and Layout:**
The house layout consists of the following rooms, along with their respective dimensions:
- **Room 1:** 30' X 18'
- Window: 5'0" X 6'0"
- **Room 2:** 18' X 14'
- Window: 5'0" X 6'0"
- **Room 3:** 10' X 8'
- **Room 4:** 22' X 16'
- Door: 2'8" X 6'8"
- **Room 5:** 26' X 20'
- Door: 2'8" X 6'8"
- Door: 20' X 3'0"
- **Room 6:** 8' X 8'
**Diagram Explanation:**
The diagram illustrates a floor plan of six rooms, with each room's dimensions clearly labeled. Additionally, the diagram shows door and window placements. The exterior walls that are exposed need to be identified and measured to calculate the total perimeter.
**Answer Calculation:**
To find the total perimeter of exposed walls:
1. **Room 1:**
- Exposed sides: 30' + 18' + 30' = 78'
2. **Room 2:**
- Exposed sides: 18' + 14' = 32'
3. **Room 3:**
- Exposed sides: (Not specified, integrated within the structure)
4. **Room 4:**
- Exposed sides: 22' + 16' (partially exposed based on interior connectivity)
5. **Room 5:**
- Exposed sides: 26' + 20' (](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fd3ebebd1-1c80-4916-8a93-3be99d13258a%2F1b75621f-10cb-411a-a545-563972836d8c%2Frwyrwzt_processed.jpeg&w=3840&q=75)
Transcribed Image Text:### Calculating the Perimeter of Exposed Wall for a House
**Problem Statement:**
What is the perimeter in feet of the exposed wall for the entire house provided?
**Guidelines:**
1. **Wall Height for All Rooms:**
- The height is 11 feet.
2. **Heat Gain and Loss Calculation:**
- For the provided drawing, round the U factor to 3 decimal places.
- Round the Heating Transfer Multiplier (HTM) to two decimal places.
3. **Rounding Off:**
- For each window, door, or surface area, round off square feet to the nearest whole number.
**Room Dimensions and Layout:**
The house layout consists of the following rooms, along with their respective dimensions:
- **Room 1:** 30' X 18'
- Window: 5'0" X 6'0"
- **Room 2:** 18' X 14'
- Window: 5'0" X 6'0"
- **Room 3:** 10' X 8'
- **Room 4:** 22' X 16'
- Door: 2'8" X 6'8"
- **Room 5:** 26' X 20'
- Door: 2'8" X 6'8"
- Door: 20' X 3'0"
- **Room 6:** 8' X 8'
**Diagram Explanation:**
The diagram illustrates a floor plan of six rooms, with each room's dimensions clearly labeled. Additionally, the diagram shows door and window placements. The exterior walls that are exposed need to be identified and measured to calculate the total perimeter.
**Answer Calculation:**
To find the total perimeter of exposed walls:
1. **Room 1:**
- Exposed sides: 30' + 18' + 30' = 78'
2. **Room 2:**
- Exposed sides: 18' + 14' = 32'
3. **Room 3:**
- Exposed sides: (Not specified, integrated within the structure)
4. **Room 4:**
- Exposed sides: 22' + 16' (partially exposed based on interior connectivity)
5. **Room 5:**
- Exposed sides: 26' + 20' (
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 3 steps with 4 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Structural Analysis](https://compass-isbn-assets.s3.amazonaws.com/isbn_cover_images/9781337630931/9781337630931_smallCoverImage.jpg)
![Structural Analysis (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134610672/9780134610672_smallCoverImage.gif)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Principles of Foundation Engineering (MindTap Cou…](https://www.bartleby.com/isbn_cover_images/9781337705028/9781337705028_smallCoverImage.gif)
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
![Structural Analysis](https://compass-isbn-assets.s3.amazonaws.com/isbn_cover_images/9781337630931/9781337630931_smallCoverImage.jpg)
![Structural Analysis (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134610672/9780134610672_smallCoverImage.gif)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Principles of Foundation Engineering (MindTap Cou…](https://www.bartleby.com/isbn_cover_images/9781337705028/9781337705028_smallCoverImage.gif)
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
![Fundamentals of Structural Analysis](https://www.bartleby.com/isbn_cover_images/9780073398006/9780073398006_smallCoverImage.gif)
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
![Sustainable Energy](https://www.bartleby.com/isbn_cover_images/9781337551663/9781337551663_smallCoverImage.gif)
![Traffic and Highway Engineering](https://www.bartleby.com/isbn_cover_images/9781305156241/9781305156241_smallCoverImage.jpg)
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning