List all of the chemicals that could be measured in this lab (exclude intermediates) in a table like a example below

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question

List all of the chemicals that could be measured in this lab (exclude intermediates) in a table like a example below 

EXPT. 8A 1-bromobutane from 1-butanol
Reaction:
H+
H,C
HO.
HBr
+
H,0
Br
Procedure:
Place 6.2 mL of 1-butanol into a 100 mL round bottom flask. Add 10 mL of 48% hydrobromic
acid (HBr) to the flask with swirling. Slowly, cautiously, and with swirling, add 4 mL of
concentrated sulfuric acid (H2SO4) to the flask. If the flask gets extremely hot, cool it in an ice
bath. Add 1-2 boiling chips to the flask and connect a reflux condenser to the top of the round
bottom flask. Connect the water hoses to the condenser (water goes in the bottom nozzle, out the
top nozzle). Since some noxious fumes may be generated during the heating period, connect a
vacuum connecting tube to the top of the condenser. Leave the ground glass joint open,
connect a vacuum hose to the gas outlet of the connecting tube. Be sure that the other end of the
vacuum hose is connected to the SINK aspirator (via the trap) and turn the aspirator water on full
blast. Feel for a slight suction when you place one of your fingers over the open joint of the
vacuum connecting tube. Once the apparatus is connected and the sink aspirator is working
correctly, heat the reaction mixture at reflux for 45 minutes. During the reflux period, perform
EXPT. 8B, SN1 reaction rate studies. Allow the flask and its contents to cool to almost room
temperature (cooling in an ice bath is acceptable). Slowly, carefully and with swirling, add 10
mL of de-ionized water to the mixture by pouring it through the condenser. Add a new boiling
chip (or two) and convert the apparatus to a simple distillation apparatus (disconnect the
vacuum). Distill the contents of the flask into a 25 mL round bottom flask which has been
immersed in an ice bath. Stop distilling when the temperature of the distillate reaches 100°C.
Remove the aqueous layer from the distillate using a transfer pipet. DO NOT THROW
ANYTHING AWAY UNTIL YOU GET VERIFICATION OF PRODUCT BY IR
SPECTROSCOPY!!! Add 5 mL of de-ionized water to the organic layer of the distillate,
mixing well with the transfer pipet. Separate the aqueous layer from the organic layer. Combine
the aqueous layer with the original aqueous layer. Wash the organic layer with 5 mL of 5 %
sodium bicarbonate solution, again separating the layers and combining the aqueous layers in a
"waste flask". Wash the organic layer once more with 5 mL of de-ionized water, separating the
layers and combining the aqueous layer with the other aqueous washes. Dry the organic layer
over anhydrous sodium sulfate. Decant or pipet the dry organic layer into a clean, dry, pre-
weighed sample bottle (with a cap). Weigh the product and run an IR spectrum on the product.
Calculate the % yield of the reaction.
and
Transcribed Image Text:EXPT. 8A 1-bromobutane from 1-butanol Reaction: H+ H,C HO. HBr + H,0 Br Procedure: Place 6.2 mL of 1-butanol into a 100 mL round bottom flask. Add 10 mL of 48% hydrobromic acid (HBr) to the flask with swirling. Slowly, cautiously, and with swirling, add 4 mL of concentrated sulfuric acid (H2SO4) to the flask. If the flask gets extremely hot, cool it in an ice bath. Add 1-2 boiling chips to the flask and connect a reflux condenser to the top of the round bottom flask. Connect the water hoses to the condenser (water goes in the bottom nozzle, out the top nozzle). Since some noxious fumes may be generated during the heating period, connect a vacuum connecting tube to the top of the condenser. Leave the ground glass joint open, connect a vacuum hose to the gas outlet of the connecting tube. Be sure that the other end of the vacuum hose is connected to the SINK aspirator (via the trap) and turn the aspirator water on full blast. Feel for a slight suction when you place one of your fingers over the open joint of the vacuum connecting tube. Once the apparatus is connected and the sink aspirator is working correctly, heat the reaction mixture at reflux for 45 minutes. During the reflux period, perform EXPT. 8B, SN1 reaction rate studies. Allow the flask and its contents to cool to almost room temperature (cooling in an ice bath is acceptable). Slowly, carefully and with swirling, add 10 mL of de-ionized water to the mixture by pouring it through the condenser. Add a new boiling chip (or two) and convert the apparatus to a simple distillation apparatus (disconnect the vacuum). Distill the contents of the flask into a 25 mL round bottom flask which has been immersed in an ice bath. Stop distilling when the temperature of the distillate reaches 100°C. Remove the aqueous layer from the distillate using a transfer pipet. DO NOT THROW ANYTHING AWAY UNTIL YOU GET VERIFICATION OF PRODUCT BY IR SPECTROSCOPY!!! Add 5 mL of de-ionized water to the organic layer of the distillate, mixing well with the transfer pipet. Separate the aqueous layer from the organic layer. Combine the aqueous layer with the original aqueous layer. Wash the organic layer with 5 mL of 5 % sodium bicarbonate solution, again separating the layers and combining the aqueous layers in a "waste flask". Wash the organic layer once more with 5 mL of de-ionized water, separating the layers and combining the aqueous layer with the other aqueous washes. Dry the organic layer over anhydrous sodium sulfate. Decant or pipet the dry organic layer into a clean, dry, pre- weighed sample bottle (with a cap). Weigh the product and run an IR spectrum on the product. Calculate the % yield of the reaction. and
Table of Chemical and Physical Properties
Boiling Point
(°C)
Molar Mass
Melting
Point (°C)
Density
(g/mL)
Hit tab in last
Name
Structure
Hazards
(g/mol)
cell to create
new row
Transcribed Image Text:Table of Chemical and Physical Properties Boiling Point (°C) Molar Mass Melting Point (°C) Density (g/mL) Hit tab in last Name Structure Hazards (g/mol) cell to create new row
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Green Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY