(k) Determine the economical cross-sectional for a single phase transmission line, 1 km transmission line a voltage of 110 kV for the following daily load cycle. 6 hr 12 hr 4hr at p.f 0.85 lagging at p.f 0.90 lagging at p.f 0.80 lagging 20 MW 5 MW 6 MW 2hr O MW Yearly downtime for maintenance is 5 days. The cost per km of line including erection is tk. (600+9000a) where 'a' is the area of conductor in cm2. The annual rate of interest and depreciation is 10% and the energy cost is 0.22 tk/kWh. The resistance of conductor is 0.173/a. Hinds: 0.22 tk/kWh = last two digits of your student ID. Only if it is 00 then use 0.11 tkAWh

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Provide correct answer

 

Id last digit 21

(k) Determine the economical cross-sectional for a single phase transmission line, 1 km
transmission line a voltage of 110 kV for the following daily load cycle.
6 hr
12 hr
at p.f 0.85 lagging
at p.f 0.90 lagging
at p.f 0.80 lagging
20 MW
5 MW
6 MW
O MW
4hr
2hr
Yearly downtime for maintenance is 5 days. The cost per km of line including erection is
tk. (600+9000a) where 'a' is the area of conductor in cm2. The annual rate of interest and
depreciation is 10% and the energy cost is 0.22 tk/kWh. The resistance of conductor is
0.173/a.
Hinds:
0.22 ik/kWh = last two digits of your student ID. Only if it is 00 then use 0.11 tk/AWh
Transcribed Image Text:(k) Determine the economical cross-sectional for a single phase transmission line, 1 km transmission line a voltage of 110 kV for the following daily load cycle. 6 hr 12 hr at p.f 0.85 lagging at p.f 0.90 lagging at p.f 0.80 lagging 20 MW 5 MW 6 MW O MW 4hr 2hr Yearly downtime for maintenance is 5 days. The cost per km of line including erection is tk. (600+9000a) where 'a' is the area of conductor in cm2. The annual rate of interest and depreciation is 10% and the energy cost is 0.22 tk/kWh. The resistance of conductor is 0.173/a. Hinds: 0.22 ik/kWh = last two digits of your student ID. Only if it is 00 then use 0.11 tk/AWh
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Logic Gate and Its Application
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,