Indicate whether the following statements are true or false. The quality of a visual inspection is affected primarily by; i) The quality of the detector (eye or camera), ii) The lighting conditions, iii) The capability to process the visual data, iv) The level of training and attention to detail Visual inspection is a very simple and basic method; therefore, it is not considered as one of the commonly employed NDT methods. The two phases involved in applying the maturity method to estimate the in-situ strength of concrete are i) Laboratory testing and ii) Field measurement of the in-place temperature history Optical aids such as mirrors, magnifiers and comparators are often used as a tool of visual inspection. The most popular nondestructive test used on concrete structures is the rebound hammer test. The two parameters needed in the Nurse-Saul Maturity Function is Apparent Activation Energy and Datum Temperature. Visual inspection is simple to perform, low in cost and relatively quick, however, it is inspector dependent and standards often do not exist. According to the maturity method, strength gain of concrete can be estimated based on the measured temperature history of concrete. While testing the properties of a concrete member, a test can only be considered as a "nondestructive test method" if absolutely no damage is given to the member. The reading of the rebound hammer is sensitive to local variations in the concrete, especially to aggregate particles near to the surface.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Indicate whether the following statements are true or false.
The quality of a visual inspection is affected primarily by; i) The quality of the detector (eye or
camera), ii) The lighting conditions, iii) The capability to process the visual data, iv) The level of
training and attention to detail
Visual inspection is a very simple and basic method; therefore, it is not considered as one of
the commonly employed NDT methods.
The two phases involved in applying the maturity method to estimate the in-situ strength of
concrete are i) Laboratory testing and ii) Field measurement of the in-place temperature
history
Optical aids such as mirrors, magnifiers and comparators are often used as a tool of visual
inspection.
The most popular nondestructive test used on concrete structures is the rebound hammer
test.
The two parameters needed in the Nurse-Saul Maturity Function is Apparent Activation
Energy and Datum Temperature.
Visual inspection is simple to perform, low in cost and relatively quick, however, it is inspector
dependent and standards often do not exist.
According to the maturity method, strength gain of concrete can be estimated based on the
measured temperature history of concrete.
While testing the properties of a concrete member, a test can only be considered as a
"nondestructive test method" if absolutely no damage is given to the member.
The reading of the rebound hammer is sensitive to local variations in the concrete, especially
to aggregate particles near to the surface.
Transcribed Image Text:Indicate whether the following statements are true or false. The quality of a visual inspection is affected primarily by; i) The quality of the detector (eye or camera), ii) The lighting conditions, iii) The capability to process the visual data, iv) The level of training and attention to detail Visual inspection is a very simple and basic method; therefore, it is not considered as one of the commonly employed NDT methods. The two phases involved in applying the maturity method to estimate the in-situ strength of concrete are i) Laboratory testing and ii) Field measurement of the in-place temperature history Optical aids such as mirrors, magnifiers and comparators are often used as a tool of visual inspection. The most popular nondestructive test used on concrete structures is the rebound hammer test. The two parameters needed in the Nurse-Saul Maturity Function is Apparent Activation Energy and Datum Temperature. Visual inspection is simple to perform, low in cost and relatively quick, however, it is inspector dependent and standards often do not exist. According to the maturity method, strength gain of concrete can be estimated based on the measured temperature history of concrete. While testing the properties of a concrete member, a test can only be considered as a "nondestructive test method" if absolutely no damage is given to the member. The reading of the rebound hammer is sensitive to local variations in the concrete, especially to aggregate particles near to the surface.
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Workplace safety
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning