If the cost of producing the hot water is $0.10 per kWh, what is the representative daily cost of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection resistance associated with water flow in the pipe may be neglected. (b) Determine the savings associated with application of a 10-mm-thick coating of urethane insulation (k = 0.026 W/m-K) to
If the cost of producing the hot water is $0.10 per kWh, what is the representative daily cost of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection resistance associated with water flow in the pipe may be neglected. (b) Determine the savings associated with application of a 10-mm-thick coating of urethane insulation (k = 0.026 W/m-K) to
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter7: Forced Convection Inside Tubes And Ducts
Section: Chapter Questions
Problem 7.20P
Related questions
Question
(a) If the cost of producing the hot water is $0.10 per kWh, what is the representative daily cost
of heat loss from an uninsulated pipe to the air per meter of pipe length? The convection
resistance associated with water flow in the pipe may be neglected.
(b) Determine the savings associated with application of a 10-mm-thick coating of urethane
insulation (k = 0.026 W/m-K) to the outer surface of the pipe.
![Hot water at 50°C is routed from one building in which it is generated to an
adjoining building in which it is used for space heating. Transfer between buildings occurs in a
steel pipe (k = 60 W/m-K) of 100-mm outside diameter and 8-mm wall thickness. During the
winter, representative environmental conditions involve air at T = -5°C and V = 3 m/s in cross
flow over the pipe.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F32fa5d6c-9c5b-4d1e-8766-3fabf2e02b29%2Fac8bbc67-f468-445f-b6f8-4906251d8883%2Ffny83mm_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Hot water at 50°C is routed from one building in which it is generated to an
adjoining building in which it is used for space heating. Transfer between buildings occurs in a
steel pipe (k = 60 W/m-K) of 100-mm outside diameter and 8-mm wall thickness. During the
winter, representative environmental conditions involve air at T = -5°C and V = 3 m/s in cross
flow over the pipe.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 6 steps with 6 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Principles of Heat Transfer (Activate Learning wi…](https://www.bartleby.com/isbn_cover_images/9781305387102/9781305387102_smallCoverImage.gif)
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
![Principles of Heat Transfer (Activate Learning wi…](https://www.bartleby.com/isbn_cover_images/9781305387102/9781305387102_smallCoverImage.gif)
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning