H.W.8: Assume that the two balanced loads in Fig.(a) for Example 8 are supplied by an 840-V rms 60-Hz line. Load 1 is Y-connected with (30 + j40) Q per phase, while load 2 is a balanced three-phase motor drawing 48 kW at a power factor of 0.8 lagging. Assuming the abc sequence, calculate: (a) the complex power absorbed by the combined load, (b) the Kvar rating of each of the three capacitors A-connected in parallel with the load to raise the power factor to unity, and (c) the current drawn from the supply at unity power factor condition. Answer: (a) 56.47 + j47.29 kVA, (b) 15.7 KVAR, (c) 38.813 A.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
I need the answer as soon as possible
H.W.8: Assume that the two balanced loads in Fig.(a) for Example 8 are supplied by an
840-V rms 60-Hz line. Load 1 is Y-connected with (30 + j40) Q per phase, while load 2 is
a balanced three-phase motor drawing 48 kW at a power factor of 0.8 lagging. Assuming
the abc sequence, calculate: (a) the complex power absorbed by the combined load, (b) the
Kvar rating of each of the three capacitors A-connected in parallel with the load to raise
the power factor to unity, and (c) the current drawn from the supply at unity power factor
condition.
Answer:
(a) 56.47 + j47.29 kVA, (b) 15.7 KVAR, (c) 38.813 A.
Transcribed Image Text:H.W.8: Assume that the two balanced loads in Fig.(a) for Example 8 are supplied by an 840-V rms 60-Hz line. Load 1 is Y-connected with (30 + j40) Q per phase, while load 2 is a balanced three-phase motor drawing 48 kW at a power factor of 0.8 lagging. Assuming the abc sequence, calculate: (a) the complex power absorbed by the combined load, (b) the Kvar rating of each of the three capacitors A-connected in parallel with the load to raise the power factor to unity, and (c) the current drawn from the supply at unity power factor condition. Answer: (a) 56.47 + j47.29 kVA, (b) 15.7 KVAR, (c) 38.813 A.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,