η X (3V2 Iz CosØ) -x100% X (3V2 12 CosØ) + X² Pcu + Pi Calculate the efficiency of the test transformer at the following loading conditions :(X=15%, 25%, 50%, 75%, 100% and 125% of I rated = 0.6A the full load), for the following load types: i. Resistive load (Coso=1). ii. Inductive load (Cos-0.8 lagging). V secondary = 220v B) From part (A) draw in the same graph paper the plot of efficiency (Y-axis) vs output power (X-axis) of the transformer for both resistive. and inductive loads. Take the scale of X-axis,each 1 cm =100 W. Take the scale of Y-axis,each 1 cm =4%. C) Discuss the plots of part (B).

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.32MCQ
icon
Related questions
Question

I need the complete solution for branches A, B, and

η
X (3V2 Iz CosØ)
-x100%
X (3V2 12 CosØ) + X² Pcu + Pi
Calculate the efficiency of the test transformer at the following
loading conditions :(X=15%, 25%, 50%, 75%, 100% and 125% of
I rated = 0.6A
the full load), for the following load types:
i. Resistive load (Coso=1).
ii. Inductive load (Cos-0.8 lagging).
V secondary = 220v
B) From part (A) draw in the same graph paper the plot of efficiency
(Y-axis) vs output power (X-axis) of the transformer for both resistive.
and inductive loads.
Take the scale of X-axis,each 1 cm =100 W.
Take the scale of Y-axis,each 1 cm =4%.
C) Discuss the plots of part (B).
Transcribed Image Text:η X (3V2 Iz CosØ) -x100% X (3V2 12 CosØ) + X² Pcu + Pi Calculate the efficiency of the test transformer at the following loading conditions :(X=15%, 25%, 50%, 75%, 100% and 125% of I rated = 0.6A the full load), for the following load types: i. Resistive load (Coso=1). ii. Inductive load (Cos-0.8 lagging). V secondary = 220v B) From part (A) draw in the same graph paper the plot of efficiency (Y-axis) vs output power (X-axis) of the transformer for both resistive. and inductive loads. Take the scale of X-axis,each 1 cm =100 W. Take the scale of Y-axis,each 1 cm =4%. C) Discuss the plots of part (B).
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning