Given corporate data on 22 public utility companies in the United States, we are interested in separating them into 2 clusters using k-means clustering algorithm. The normalized values of Rate of Return on capital (RoR) and Load Factor (LF) of five of them are listed below. Utility Company Normalized RoR Normalized LF Texas Utilities Co. 0.429 -0.667 Florida Power & Light Co. 1.232 0.678 Oklahoma Gas & Electric Co. 0.563 -1.609 Central Louisiana Co. 2.078 -0.892 The Southern Co. 0.830 -0.062 Suppose the other 17 utility companies have been separated into two clusters (cluster 1 and cluster 2) with the following centroids: Cluster Centroid RoR Centroid LF 1 0.564 -0.404 2 0.494 -0.689 Round your answers to 3 digits after the decimal point. Please compute the Euclidean distance between each of the above five utility companies and each of the clusters. Distance of Texas Utilities Co. to the centroid of cluster 1 is . Distance of Texas Utilities Co. to the centroid of cluster 2 is . Distance of Florida Power & Light Co. to the centroid of cluster 1 is . Distance of Florida Power & Light Co. to the centroid of cluster 2 is . Distance of Oklahoma Gas & Electric Co. to the centroid of cluster 1 is . Distance of Oklahoma Gas & Electric Co. to the centroid of cluster 2 is . Distance of Central Louisiana Co. to the centroid of cluster 1 is . Distance of Central Louisiana Co. to the centroid of cluster 2 is . Distance of The Southern Co. to the centroid of cluster 1 is . Distance of The Southern Co. to the centroid of cluster 2 is . Please assign each of the above five utility companies to one of the two clusters. Texas Utilities Co. should be assigned to (Cluster 1 or Cluster 2?). Florida Power & Light Co. should be assigned to . Oklahoma Gas & Electric Co. should be assigned to . Central Louisiana Co. should be assigned to . The Southern Co. should be assigned to . Texas Utilities Co. 0.429 -0.667 Florida Power & Light Co. 1.232 0.678 Oklahoma Gas & Electric Co. 0.563 -1.609 Central Louisiana Co. 2.078 -0.892 The Southern Co. 0.830 -0.062

Database System Concepts
7th Edition
ISBN:9780078022159
Author:Abraham Silberschatz Professor, Henry F. Korth, S. Sudarshan
Publisher:Abraham Silberschatz Professor, Henry F. Korth, S. Sudarshan
Chapter1: Introduction
Section: Chapter Questions
Problem 1PE
icon
Related questions
Question
Given corporate data on 22 public utility companies in the United States, we are interested in separating them into 2 clusters using k-means clustering algorithm. The normalized values of Rate of Return on capital (RoR) and Load Factor (LF) of five of them are listed below. Utility Company Normalized RoR Normalized LF Texas Utilities Co. 0.429 -0.667 Florida Power & Light Co. 1.232 0.678 Oklahoma Gas & Electric Co. 0.563 -1.609 Central Louisiana Co. 2.078 -0.892 The Southern Co. 0.830 -0.062 Suppose the other 17 utility companies have been separated into two clusters (cluster 1 and cluster 2) with the following centroids: Cluster Centroid RoR Centroid LF 1 0.564 -0.404 2 0.494 -0.689 Round your answers to 3 digits after the decimal point. Please compute the Euclidean distance between each of the above five utility companies and each of the clusters. Distance of Texas Utilities Co. to the centroid of cluster 1 is . Distance of Texas Utilities Co. to the centroid of cluster 2 is . Distance of Florida Power & Light Co. to the centroid of cluster 1 is . Distance of Florida Power & Light Co. to the centroid of cluster 2 is . Distance of Oklahoma Gas & Electric Co. to the centroid of cluster 1 is . Distance of Oklahoma Gas & Electric Co. to the centroid of cluster 2 is . Distance of Central Louisiana Co. to the centroid of cluster 1 is . Distance of Central Louisiana Co. to the centroid of cluster 2 is . Distance of The Southern Co. to the centroid of cluster 1 is . Distance of The Southern Co. to the centroid of cluster 2 is . Please assign each of the above five utility companies to one of the two clusters. Texas Utilities Co. should be assigned to (Cluster 1 or Cluster 2?). Florida Power & Light Co. should be assigned to . Oklahoma Gas & Electric Co. should be assigned to . Central Louisiana Co. should be assigned to . The Southern Co. should be assigned to . Texas Utilities Co. 0.429 -0.667 Florida Power & Light Co. 1.232 0.678 Oklahoma Gas & Electric Co. 0.563 -1.609 Central Louisiana Co. 2.078 -0.892 The Southern Co. 0.830 -0.062
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Complex Datatypes
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, computer-science and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Database System Concepts
Database System Concepts
Computer Science
ISBN:
9780078022159
Author:
Abraham Silberschatz Professor, Henry F. Korth, S. Sudarshan
Publisher:
McGraw-Hill Education
Starting Out with Python (4th Edition)
Starting Out with Python (4th Edition)
Computer Science
ISBN:
9780134444321
Author:
Tony Gaddis
Publisher:
PEARSON
Digital Fundamentals (11th Edition)
Digital Fundamentals (11th Edition)
Computer Science
ISBN:
9780132737968
Author:
Thomas L. Floyd
Publisher:
PEARSON
C How to Program (8th Edition)
C How to Program (8th Edition)
Computer Science
ISBN:
9780133976892
Author:
Paul J. Deitel, Harvey Deitel
Publisher:
PEARSON
Database Systems: Design, Implementation, & Manag…
Database Systems: Design, Implementation, & Manag…
Computer Science
ISBN:
9781337627900
Author:
Carlos Coronel, Steven Morris
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Computer Science
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education