For the circuit magnetic circuit above find the value of I required to establish a flux in the gap of 9x 10*Wb. And the material of the core is cast iron. N = 200 turns.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
a-
Фт
0.002 m
1
Area =
2 x 104 m?
2
V =
200 turns
Area for sections other than bg = 5 × 104 m?
lab = log = lgh = Ina = 0.2 m
Ibe = ! = 0.1 m, led = leg = 0.099 m
%3D
For the cireuit magnetic eircuit above find the value of I required to establish a flux in the gap of
9x 10*wb. And the material of the core is cast iron. N = 200 turns.
Transcribed Image Text:a- Фт 0.002 m 1 Area = 2 x 104 m? 2 V = 200 turns Area for sections other than bg = 5 × 104 m? lab = log = lgh = Ina = 0.2 m Ibe = ! = 0.1 m, led = leg = 0.099 m %3D For the cireuit magnetic eircuit above find the value of I required to establish a flux in the gap of 9x 10*wb. And the material of the core is cast iron. N = 200 turns.
b.
Cast steel
Ф
The figure shows a core with mean path length of 40cm. There is a small air gap of 0.05cm in the
structure. The cross sectional area of the core is 19 cm?.
Assume that fringing in the air gap increases the effective cross sectional area of air gap
by 5%. The no of turns is 400. Given this information. Find
a) The total reluctance of the flux path (cast steel plus air gap)
b) The current required to produce a flux density of 0.5T in the air gap
Transcribed Image Text:b. Cast steel Ф The figure shows a core with mean path length of 40cm. There is a small air gap of 0.05cm in the structure. The cross sectional area of the core is 19 cm?. Assume that fringing in the air gap increases the effective cross sectional area of air gap by 5%. The no of turns is 400. Given this information. Find a) The total reluctance of the flux path (cast steel plus air gap) b) The current required to produce a flux density of 0.5T in the air gap
Expert Solution
steps

Step by step

Solved in 6 steps with 1 images

Blurred answer
Knowledge Booster
Magnetic force
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,