Figure below shows the ladder diagram of Counting and Packaging System. Based on the diagram, choose the correct statement regarding the system and components. E0.02 Q: 100.01 ০: 100.00 box conveyor main relay box sensor Co02 apple counter Q: 100.00 9 Q: 100.02 t0.02 HH C002 lamp for box main relay box sensor apple counter Q: 100.03 3 13 Q: 100.00 t0.02 C002 apple conveyor main relay box sensor apple counter Q: 100.00 HH main relay 4. t0.03 17 CNT Counter apple sensor apple counter Counter number E0.04 002 reset button 1 0.02 #3 Set value box sensor O a. Apple Counter is also used to turn ON the box conveyor O b. The number of main relay used in the system is 4. O c.If the physical contact of box sensor is Normally Open, when the box sensor detects a box, the indicator lamp will turn ON. O d. The physical contact for reset button is Normally Closed. O e. The number of input is 3 and the number of output is 4. O f. TIMO10 can replace the address CNTO02 for Counter function. 80
Figure below shows the ladder diagram of Counting and Packaging System. Based on the diagram, choose the correct statement regarding the system and components. E0.02 Q: 100.01 ০: 100.00 box conveyor main relay box sensor Co02 apple counter Q: 100.00 9 Q: 100.02 t0.02 HH C002 lamp for box main relay box sensor apple counter Q: 100.03 3 13 Q: 100.00 t0.02 C002 apple conveyor main relay box sensor apple counter Q: 100.00 HH main relay 4. t0.03 17 CNT Counter apple sensor apple counter Counter number E0.04 002 reset button 1 0.02 #3 Set value box sensor O a. Apple Counter is also used to turn ON the box conveyor O b. The number of main relay used in the system is 4. O c.If the physical contact of box sensor is Normally Open, when the box sensor detects a box, the indicator lamp will turn ON. O d. The physical contact for reset button is Normally Closed. O e. The number of input is 3 and the number of output is 4. O f. TIMO10 can replace the address CNTO02 for Counter function. 80
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Question
Answers can be select more than one

Transcribed Image Text:Figure below shows the ladder diagram of Counting and Packaging System.
Based on the diagram, choose the correct statement regarding the system and components.
Q: 100.00
E 0.02
Q: 100.01
box conveyor
main reiay
box sensor
Co02
apple counter
Q: 100.00
HH
main relay
2
E0.02
C002
Q: 100.02
9
HH
lamp for box
box sensor
apple counter
t 0.02
HH
box sensor
Q: 100.00
CO02
Q: 100.03
13
apple conveyor
main relay
apple counter
Q: 100.00
E0.03
17
main relay
apple sensor
CNT
Counter
1: 0.04
HH
reset button
apple counter
Counter number
002
: 0.02
# 3
Set value
box sensor
O a. Apple Counter is also used to turn ON the box conveyor
O b. The number of main relay used in the system is 4.
O c.If the physical contact of box sensor is Normally Open, when the box sensor detects a box, the indicator lamp will turn ON.
O d. The physical contact for reset button is Normally Closed.
O e. The number of input is 3 and the number of output is 4.
O f. TIMO10 can replace the address CNTO02 for Counter function.
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education

Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON

Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,