Example 2.3 A balanced, negative sequence, A-connected source has an internal impedance of 0.018+j0.162 £2 per phase. The internal phase voltage of the generator is 600 V. The source is connected to a Y-connected load having an impedance of 7.92-j6.35 § per phase through a distribution line having an impedance of 0.074+j0.296 £2 per phase. a) Construct a single phase equivalent circuit of the three phase system. b) Calculate the three line current IA, IB and IC c) Calculate the three line to neutral voltages at the load V AN, VBN and V CN d) Calculate the three line to line voltages at the load V AB' VBC and V CA

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.32MCQ: While the instantaneous electric power delivered by a single-phase generator under balanced...
icon
Related questions
Question
Power Transmission and Distribution,Basic Concept in power System.I would like to understand the details of the method for doing this. Thank you in advance for your answer.
Example 2.3
A balanced, negative sequence, A-connected source has an internal impedance of
0.018+j0.162 £2 per phase. The internal phase voltage of the generator is 600 V. The
source is connected to a Y-connected load having an impedance of 7.92-j6.35 § per
phase through a distribution line having an impedance of 0.074+j0.296 £2 per phase.
a) Construct a single phase equivalent circuit of the three phase system.
b) Calculate the three line current IA, IB and IC
c) Calculate the three line to neutral voltages at the load V
AN, VBN and V
CN
d) Calculate the three line to line voltages at the load V
AB' VBC and V
CA
Transcribed Image Text:Example 2.3 A balanced, negative sequence, A-connected source has an internal impedance of 0.018+j0.162 £2 per phase. The internal phase voltage of the generator is 600 V. The source is connected to a Y-connected load having an impedance of 7.92-j6.35 § per phase through a distribution line having an impedance of 0.074+j0.296 £2 per phase. a) Construct a single phase equivalent circuit of the three phase system. b) Calculate the three line current IA, IB and IC c) Calculate the three line to neutral voltages at the load V AN, VBN and V CN d) Calculate the three line to line voltages at the load V AB' VBC and V CA
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer