Example 2: The following data apply to an air-conditioning system RSH=11.6 kW RLH=11.6 Kw In side condition 25°C & RH=50% & outside condition 35°C DBT & 27.8°C WBT Return air from the room is mixed with the outside air before entering the cooling coil a ratio 4:1 Return air from the room is mixed with the air leaving the cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The air may be reheated if necessary before suppling the condition, assume tdp=10°C. find 1- Supply air condition to the room 2- Refrigeration load (Colling coil load) 3- Total refrigeration capacity d- The quantity of fresh air supplied

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Example 2: The following data apply to an air-conditioning
system
RSH=11.6 kW
RLH=11.6 Kw
In side condition 25°C & RH=50% & outside condition 35°C DBT
& 27.8°C WBT
Return air from the room is mixed with the outside air before
entering the cooling coil a ratio 4:1
Return air from the room is mixed with the air leaving the
cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The
air may be reheated if necessary before suppling the condition,
assume tdp=10°C. find
1- Supply air condition to the room
2- Refrigeration load (Colling coil load)
3- Total refrigeration capacity
d- The quantity of fresh air supplied
Transcribed Image Text:Example 2: The following data apply to an air-conditioning system RSH=11.6 kW RLH=11.6 Kw In side condition 25°C & RH=50% & outside condition 35°C DBT & 27.8°C WBT Return air from the room is mixed with the outside air before entering the cooling coil a ratio 4:1 Return air from the room is mixed with the air leaving the cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The air may be reheated if necessary before suppling the condition, assume tdp=10°C. find 1- Supply air condition to the room 2- Refrigeration load (Colling coil load) 3- Total refrigeration capacity d- The quantity of fresh air supplied
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY