E.34. The formwork for a 6-in.-thick reinforced concrete floor slab of normal weight consists of
4 in. Class II plyform sheathing supported by 2 x 6 in. joists spaced 2 ft. (o.c), which in
turn are supported by 2 x 8 in. stringers spaced 4 ft. (0.c). The stringers are themselves
supported by shores spaced 4 ft. on centers.
The joists and stringers are constructed with Douglas fir, coastal construction, and are to
be used many times. The allowable flexural stress in the fir members is 1875 psi, the
allowable horizontal shear stress is 180 psi, and the modulus of elasticity is 1,760,000 psi.
For the plyform the corresponding values are 1330 psi, 72 psi, and 1,430,000 psi, with the
stress applied parallel with the face grain. Using a live load of 150 psf, a) Check the
bending and shear stresses in the sheathing, joists and stringers; b) Check deflections
assuming that the maximum permissible deflection of each of these elements is L/360 for
all loads.
11.2. Redesign the formwork system for Class Exercise E34 and select a new adequate plyform
and stringer for this formwork.
Transcribed Image Text:E.34. The formwork for a 6-in.-thick reinforced concrete floor slab of normal weight consists of 4 in. Class II plyform sheathing supported by 2 x 6 in. joists spaced 2 ft. (o.c), which in turn are supported by 2 x 8 in. stringers spaced 4 ft. (0.c). The stringers are themselves supported by shores spaced 4 ft. on centers. The joists and stringers are constructed with Douglas fir, coastal construction, and are to be used many times. The allowable flexural stress in the fir members is 1875 psi, the allowable horizontal shear stress is 180 psi, and the modulus of elasticity is 1,760,000 psi. For the plyform the corresponding values are 1330 psi, 72 psi, and 1,430,000 psi, with the stress applied parallel with the face grain. Using a live load of 150 psf, a) Check the bending and shear stresses in the sheathing, joists and stringers; b) Check deflections assuming that the maximum permissible deflection of each of these elements is L/360 for all loads. 11.2. Redesign the formwork system for Class Exercise E34 and select a new adequate plyform and stringer for this formwork.
Expert Solution
steps

Step by step

Solved in 3 steps with 4 images

Blurred answer
Knowledge Booster
Sizing joists and rafters
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning