Determine the required water supply flow volume (gpm) required for a planned development that will have a population of 13,000 people and a fire demand based on a 10,000 ft² upholstering shop built of frame construction. What is the needed fire flow (gpm) and duration (hrs)? How large of a reservoir or storage tank is needed (gal)? Provide answers to 0 decimal places. Design supply flow: Needed Fire Flow: NFF should be rounded: to nearest 250 gpm (1000 Lpm) if < 2500 gpm (9000 Lpm) to nearest 500 gpm (2000 Lpm) if2 2500 gpm (9000 Lpm) NFF: Commercial construction, 500 gpm (2000 Lpm) NFF ≤ 12000 gpm (45000 Lpm) 1- and 2-family dwellings of 1 or 2 stories, use NFF listed in Table 3.5 Other habitable buildings, NFF 3500 gpm (13000 Lpm) Calculated value of C should be rounded to nearest 250 gpm (1000 Lpm) Minimum value of C: 500 gpm (2000 Lpm) Maximum value of C: 8000 gpm (30,000 Lpm) for construction classes 1 and 2 6000 gpm (23,000 Lpm) for construction classes 3, 4, 5, and 6 6000 gpm (23,000 Lpm) for a one-story building of any class NFF duration: Storage capacity: gpm gpm hrs gál
Determine the required water supply flow volume (gpm) required for a planned development that will have a population of 13,000 people and a fire demand based on a 10,000 ft² upholstering shop built of frame construction. What is the needed fire flow (gpm) and duration (hrs)? How large of a reservoir or storage tank is needed (gal)? Provide answers to 0 decimal places. Design supply flow: Needed Fire Flow: NFF should be rounded: to nearest 250 gpm (1000 Lpm) if < 2500 gpm (9000 Lpm) to nearest 500 gpm (2000 Lpm) if2 2500 gpm (9000 Lpm) NFF: Commercial construction, 500 gpm (2000 Lpm) NFF ≤ 12000 gpm (45000 Lpm) 1- and 2-family dwellings of 1 or 2 stories, use NFF listed in Table 3.5 Other habitable buildings, NFF 3500 gpm (13000 Lpm) Calculated value of C should be rounded to nearest 250 gpm (1000 Lpm) Minimum value of C: 500 gpm (2000 Lpm) Maximum value of C: 8000 gpm (30,000 Lpm) for construction classes 1 and 2 6000 gpm (23,000 Lpm) for construction classes 3, 4, 5, and 6 6000 gpm (23,000 Lpm) for a one-story building of any class NFF duration: Storage capacity: gpm gpm hrs gál
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
Expert Solution
Step by step
Solved in 9 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning