3. A commercial cubical refrigerator, 3 m on a side, has a composite wall consisting of an exterior sheet of 6.35-mm-thick plain carbon steel, an intermediate layer of 125-mm-thick cork insulation, and an inner sheet of 6.35-mm thick aluminum alloy (2024). Adhesive interfaces between the insulation and the metallic sheets are characterized by a thermal contact resistance of R=2.5 x 104 m²-K/W. What is the steady-state cooling load that must be maintained by the refrigerator when the outer and inner surfaces of all six sides are 25°C and -5°C, respectively?

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question

solve, show all steps and solutions. list assumptions and concluding comment 

heat transfer. show resistor diagram for Rs as well

use k aluminum = 177

and k carbon steel = 60.5

3. A commercial cubical refrigerator, 3 m on a side, has a composite wall consisting of an exterior sheet of
6.35-mm-thick plain carbon steel, an intermediate layer of 125-mm-thick cork insulation, and an inner
sheet of 6.35-mm thick aluminum alloy (2024). Adhesive interfaces between the insulation and the
metallic sheets are characterized by a thermal contact resistance of R=2.5 × 104 m²-K/W. What is the
steady-state cooling load that must be maintained by the refrigerator when the outer and inner surfaces of
all six sides are 25°C and -5°C, respectively?
steady-state cooling load that must be maintained
n the outer and inner surface
Transcribed Image Text:3. A commercial cubical refrigerator, 3 m on a side, has a composite wall consisting of an exterior sheet of 6.35-mm-thick plain carbon steel, an intermediate layer of 125-mm-thick cork insulation, and an inner sheet of 6.35-mm thick aluminum alloy (2024). Adhesive interfaces between the insulation and the metallic sheets are characterized by a thermal contact resistance of R=2.5 × 104 m²-K/W. What is the steady-state cooling load that must be maintained by the refrigerator when the outer and inner surfaces of all six sides are 25°C and -5°C, respectively? steady-state cooling load that must be maintained n the outer and inner surface
Expert Solution
steps

Step by step

Solved in 6 steps with 6 images

Blurred answer
Follow-up Questions
Read through expert solutions to related follow-up questions below.
Follow-up Question

Cork k =.045 also all are 300 K values ... please resolve 

Solution
Bartleby Expert
SEE SOLUTION
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher: