Cooler 2 currently operates using R-134a as a refrigerant. The 2nd stage of your project is to study the possibility of exchanging this working fluid for ammonia (R-717), which is less harmful to the environment. To make this choice, you must evaluate the performance of Cooler 2 by calculating the coefficient of cycle performance (COP) for each fluid. Chiller 2 also operates at a flow rate of 1.4 kg/s, whose evaporation and condensing temperatures are -10 °C and 30 °C. The evaporation (1 → 2) and condensation (3 → 4) steps operate at constant pressures, so the pressure of each of these two steps is the saturation pressure relative to the operating temperature. For this 2nd step, you must deliver the project report with the following information: 2.a. Cycle COP using R-134a as refrigerant; 2.b. Cycle COP using R-717 as refrigerant; 2.c. Your opinion as an engineer on which of the two working fluids has a better performance, exclusively analyzing the cycle performance coefficients obtained.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
100%

Cooler 2 currently operates using R-134a as a refrigerant. The 2nd stage of your project is to study the possibility of exchanging this working fluid for ammonia (R-717), which is less harmful to the environment. To make this choice, you must evaluate the performance of Cooler 2 by calculating the coefficient of cycle performance (COP) for each fluid. Chiller 2 also operates at a flow rate of 1.4 kg/s, whose evaporation and condensing temperatures are -10 °C and 30 °C. The evaporation (1 → 2) and condensation (3 → 4) steps operate at constant pressures, so the pressure of each of these two steps is the saturation pressure relative to the operating temperature. For this 2nd step, you must deliver the project report with the following information:

2.a. Cycle COP using R-134a as refrigerant;

2.b. Cycle COP using R-717 as refrigerant;

2.c. Your opinion as an engineer on which of the two working fluids has a better performance, exclusively analyzing the cycle performance coefficients obtained.

Expert Solution
steps

Step by step

Solved in 6 steps with 1 images

Blurred answer
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY