ccount will be recorded when you upload files nd submit this form. Your email is not part of our response. Required Intitled Question Q1: Refrigerant-134a is the working fluid in an ideal compression refrigeration cycle. The refrigerant leaves the evaporator-20°C and has a condenser pressure of 0.9 MPa. The mass flow rate is 3 kg/min. Find COP, COP, Cat for same Tma and Tmin , and the tons of refrigeration. 1 Add file

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
ervi n.k2603@sadiq.edu.iq SwMO Aslacel
Asiacell
jjs 0701
The name and photo associated with your Google
account will be recorded when you upload files
and submit this form. Your email is not part of
070E
your response.
Required
Untitled Question *
Q1: Refrigerant-134a is the working fluid in an ideal compression refrigeration cycle.
The refrigerant leaves the evaporator -20°C and has a condenser pressure of 0.9 MPa.
The mass flow rate is 3 kg/min. Find COP, COPR Carnot for same Tma and Tmin , and the
tons of refrigeration.
1 Add file
Untitled Question *
Q2: A simple VCRC using R-134a operates with a condensing temperature of 30°c and
an evaporating temperature of -20°c .The system produces 50 kw of refrigeration.
Determine the : a) Thermodynamic property values at the four main state points
of the cycle, b) COP, c) Rate of refrigerant flow.
1 Add file
Submit
Clear form
This form was created inside of tmam Ja'afar Al-Sadia
وأثق السلأمي
11:41p äc lull 22.04.02
Transcribed Image Text:ervi n.k2603@sadiq.edu.iq SwMO Aslacel Asiacell jjs 0701 The name and photo associated with your Google account will be recorded when you upload files and submit this form. Your email is not part of 070E your response. Required Untitled Question * Q1: Refrigerant-134a is the working fluid in an ideal compression refrigeration cycle. The refrigerant leaves the evaporator -20°C and has a condenser pressure of 0.9 MPa. The mass flow rate is 3 kg/min. Find COP, COPR Carnot for same Tma and Tmin , and the tons of refrigeration. 1 Add file Untitled Question * Q2: A simple VCRC using R-134a operates with a condensing temperature of 30°c and an evaporating temperature of -20°c .The system produces 50 kw of refrigeration. Determine the : a) Thermodynamic property values at the four main state points of the cycle, b) COP, c) Rate of refrigerant flow. 1 Add file Submit Clear form This form was created inside of tmam Ja'afar Al-Sadia وأثق السلأمي 11:41p äc lull 22.04.02
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY