b) The old Hydraulics laboratory in Mechanical Engineering used a roof tank to supply apparatus with water at a nearly constant head. The water was collected in an under floor sump, and then pumped back to the roof tank after the experiment. The flow rate was 10 litre s1. The tank was 6m above the sump, and the length of the pipe route was 15 m. The old 6" pipes are now heavily corroded (k = 7.5 mm). The old pump has been scrapped. What head AH would be specified for a pump to restore the system using the old pipes? What would the pump power be? If the pipes were replaced with 150 mm diameter PVC pipes, what pump AH would be required? ROOF TANK 6m PUMP SUMP

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Topic Video
Question

hydraulics

b) The old Hydraulics laboratory in Mechanical Engineering used a roof tank to
supply apparatus with water at a nearly constant head. The water was
collected in an under floor sump, and then pumped back to the roof tank
after the experiment. The flow rate was 10 litre s1. The tank was 6m above
the sump, and the length of the pipe route was 15 m. The old 6" pipes are
now heavily corroded (k = 7.5 mm). The old pump has been scrapped. What
head AH would be specified for a pump to restore the system using the old
pipes? What would the pump power be? If the pipes were replaced with 150
mm diameter PVC pipes, what pump AH would be required?
ROOF
TANK
6m
PUMP
SUMP
Transcribed Image Text:b) The old Hydraulics laboratory in Mechanical Engineering used a roof tank to supply apparatus with water at a nearly constant head. The water was collected in an under floor sump, and then pumped back to the roof tank after the experiment. The flow rate was 10 litre s1. The tank was 6m above the sump, and the length of the pipe route was 15 m. The old 6" pipes are now heavily corroded (k = 7.5 mm). The old pump has been scrapped. What head AH would be specified for a pump to restore the system using the old pipes? What would the pump power be? If the pipes were replaced with 150 mm diameter PVC pipes, what pump AH would be required? ROOF TANK 6m PUMP SUMP
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Fluid Statics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY