(b) A 2.89kV/230V single phase transformer used in a local distribution network has the equivalent circuit parameters shown in Table Q3b. Determine: (i) The transformer turns ratio. (ii) The secondary voltage, current and power (W) given a 10 2 resistive load. (iii) The efficiency and voltage regulation at this load. (iv) The load power when operating the transformer at maximum efficiency. The transformer primary current and power factor when operating under no load (open circuit) conditions. (v) hase e . - atonc 11 L T atina Parameter Value Units Re 46 10 Хм Rieg Xieq 78 200 Ω Table Q3b

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
(b)
A 2.89kV/230V single phase transformer used in a local distribution network has
the equivalent circuit parameters shown in Table Q3b.
Determine:
(i)
The transformer turns ratio.
(ii)
The secondary voltage, current and power (W) given a 10 Q resistive
load.
(iii)
The efficiency and voltage regulation at this load.
(iv)
The load power when operating the transformer at maximum efficiency.
The transformer primary current and power factor when operating under no
load (open circuit) conditions.
(v)
hase e
- etone 11 LIIA.
atina
Parameter Value
Units
Re
46
kQ
Хм
Rieg
X1eq
10
78
Ω
200
Ω
Table Q3b
Transcribed Image Text:(b) A 2.89kV/230V single phase transformer used in a local distribution network has the equivalent circuit parameters shown in Table Q3b. Determine: (i) The transformer turns ratio. (ii) The secondary voltage, current and power (W) given a 10 Q resistive load. (iii) The efficiency and voltage regulation at this load. (iv) The load power when operating the transformer at maximum efficiency. The transformer primary current and power factor when operating under no load (open circuit) conditions. (v) hase e - etone 11 LIIA. atina Parameter Value Units Re 46 kQ Хм Rieg X1eq 10 78 Ω 200 Ω Table Q3b
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Y parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,