At the commencement of compression in the reciprocating compressor of a refrigeration plant the refrigerant is dry saturated at 1 bar. The compression process follows the law pV = constant until the pressure is 10 bar. Using the properties of refrigerant given in the table, interpolating where necessary, calculate: (a) the work done on the refrigerant during the process (b) the change of internal energy on the refrigerant during the process (c) the heat transfer through the cylinder wall during the process Saturation values Superheat values at 10 bar P br hg V h bar °C m'/kg kJ/kg m'/kg kJ/kg 1 -30 0.160 8.9 174.2 10 42 0.018 76.3 203.8 0.020 224.0

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
At the commencement of compression in the reciprocating compressor of a
refrigeration plant the refrigerant is dry saturated at 1 bar. The compression process
follows the law pV = constant until the pressure is 10 bar. Using the properties of
refrigerant given in the table, interpolating where necessary, calculate:
(a) the work done on the refrigerant during the process
(b) the change of internal energy on the refrigerant during the process
(c) the heat transfer through the cylinder wall during the process
Saturation values
Superheat values at
10 bar
P
bar
hr
he
kJkg
V
h
°C
m'/kg
0.160
m'/kg
kJ/kg
1
-30
8.9
174.2
10
42
0.018
76.3
203.8
0.020
224.0
Transcribed Image Text:At the commencement of compression in the reciprocating compressor of a refrigeration plant the refrigerant is dry saturated at 1 bar. The compression process follows the law pV = constant until the pressure is 10 bar. Using the properties of refrigerant given in the table, interpolating where necessary, calculate: (a) the work done on the refrigerant during the process (b) the change of internal energy on the refrigerant during the process (c) the heat transfer through the cylinder wall during the process Saturation values Superheat values at 10 bar P bar hr he kJkg V h °C m'/kg 0.160 m'/kg kJ/kg 1 -30 8.9 174.2 10 42 0.018 76.3 203.8 0.020 224.0
Expert Solution
steps

Step by step

Solved in 3 steps with 16 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The