At a 220 kV substation of apowersystem, it is given that the three-phase fault level is 4000 MVA and single-line toground fault level is 5000 MVA. Neglecting the resistance and the shunt susceptances ofthe system The positive sequence driving pointeactance at the bus is:
At a 220 kV substation of apowersystem, it is given that the three-phase fault level is 4000 MVA and single-line toground fault level is 5000 MVA. Neglecting the resistance and the shunt susceptances ofthe system The positive sequence driving pointeactance at the bus is:
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter9: Unsymmetrical Faults
Section: Chapter Questions
Problem 9.8P
Related questions
Question
![At a 220 kV substation of apowersystem, it is given that the three-phase fault level is 4000 MVA and
single-line toground fault level is 5000 MVA. Neglecting the resistance and the shunt susceptances
ofthe system
The positive sequence driving pointeactance at the bus is:](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Ffad7f22c-7704-42d6-9983-2c745e3b55a3%2Fdf9511fa-00b3-4fd2-a9f1-40be8cbf190e%2Fwqxsx2p_processed.jpeg&w=3840&q=75)
Transcribed Image Text:At a 220 kV substation of apowersystem, it is given that the three-phase fault level is 4000 MVA and
single-line toground fault level is 5000 MVA. Neglecting the resistance and the shunt susceptances
ofthe system
The positive sequence driving pointeactance at the bus is:
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning