As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside temperature is 103.5°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input to the air conditioner compressor is 3.45 hp. Inside, 70° F Evaporator 30,000 Btu/h Refrigerant loop Compressor Outside Condenser Qu Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot temperatures.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside
temperature is 103.5°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input
to the air conditioner compressor is 3.45 hp.
Step 1
B
Inside, 70° F
Determine the coefficient of performance for the air conditioner.
=
Evaporator
i
30,000 Btu/h
Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of
performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot
temperatures.
Refrigerant loop
Compressor
Outside
Q +
Condenser
Transcribed Image Text:As shown in the figure, an air conditioner operating at steady state maintains a dwelling at 70°F on a day when the outside temperature is 103.5°F. The rate of heat transfer into the dwelling through the walls and roof is 30,000 Btu/h and the net power input to the air conditioner compressor is 3.45 hp. Step 1 B Inside, 70° F Determine the coefficient of performance for the air conditioner. = Evaporator i 30,000 Btu/h Determine the coefficient of performance of the air conditioner. Determine the power input required, in hp, and the coefficient of performance for a reversible air conditioner providing the same cooling effect while operating between the same cold and hot temperatures. Refrigerant loop Compressor Outside Q + Condenser
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY