An interior column is to be designed as a part of an unbraced frame system, located at ground floor. It is to be pin-supported at the foundation end, and it is to be connected by two W14x82 girders and W18x130 column at the other end. All of the members, including the column described, are made of ASTM A992 steel. Architectural specifications require that the column is to be designed as a rolled W-section with depth of 21 inches. The column is expected to carry axial compressive load of 100 kN dead load and 300 kN live load. Length of girders is 5 meters and length of columns is 3.5 meters. Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment
An interior column is to be designed as a part of an unbraced frame system, located at ground floor. It is to be pin-supported at the foundation end, and it is to be connected by two W14x82 girders and W18x130 column at the other end. All of the members, including the column described, are made of ASTM A992 steel. Architectural specifications require that the column is to be designed as a rolled W-section with depth of 21 inches. The column is expected to carry axial compressive load of 100 kN dead load and 300 kN live load. Length of girders is 5 meters and length of columns is 3.5 meters. Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
100%
SITUATION 2 An interior column is to be designed as a part of an unbraced frame system, located at ground floor. It is to be pin-supported at the foundation end, and it is to be connected by two W14x82 girders and W18x130 column at the other end. All of the members, including the column described, are made of ASTM A992 steel. Architectural specifications require that the column is to be designed as a rolled W-section with depth of 21 inches. The column is expected to carry axial compressive load of 100 kN dead load and 300 kN live load. Length of girders is 5 meters and length of columns is 3.5 meters.
Select the best section that should be used for the said column.
For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment of inertia for columns. Use ASD specifications from 2015 NSCP Vol. 1. Type your final answer/s in the text box below.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 6 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning