An interior column is to be designed as a part of an unbraced frame system, located at the ground floor. It is to be pin- supported at the foundation end, and it is to be connected by two W14x82 girders and a W18x130 column at the other end. All of the members, including the column described, are mad of ASTM A992 steel. Architectural specifications require that the column is to be designed as a rolled W-section with a depth of 21 inches. The column is expected to carry the axial compressive load of 250 kN dead load and 300 kN live load. The length of the girders and columns are 5 meters and 3.5 meters respectively. Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment inertia for girders and minor axis moment of inertia for columns. Use LRFD specifications from 2015 NSCP Vol. 1.

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter5: Beams
Section: Chapter Questions
Problem 5.13.2P
icon
Related questions
Question

Column 

An interior column is to be designed as a part of an unbraced
frame system, located at the ground floor. It is to be pin-
supported at the foundation end, and it is to be connected by
two W14x82 girders and a W18x130 column at the other end.
All of the members, including the column described, are made
of ASTM A992 steel. Architectural specifications require that
the column is to be designed as a rolled W-section with a
depth of 21 inches. The column is expected to carry the axial
compressive load of 250 kN dead load and 300 kN live load.
The length of the girders and columns are 5 meters and 3.5
meters respectively. Select the best section that should be
used for the said column. For determining effective length
factors, neglect inelastic action; and use major axis moment of
inertia for girders and minor axis moment of inertia for
columns. Use LRFD specifications from 2015 NSCP Vol. 1.
Transcribed Image Text:An interior column is to be designed as a part of an unbraced frame system, located at the ground floor. It is to be pin- supported at the foundation end, and it is to be connected by two W14x82 girders and a W18x130 column at the other end. All of the members, including the column described, are made of ASTM A992 steel. Architectural specifications require that the column is to be designed as a rolled W-section with a depth of 21 inches. The column is expected to carry the axial compressive load of 250 kN dead load and 300 kN live load. The length of the girders and columns are 5 meters and 3.5 meters respectively. Select the best section that should be used for the said column. For determining effective length factors, neglect inelastic action; and use major axis moment of inertia for girders and minor axis moment of inertia for columns. Use LRFD specifications from 2015 NSCP Vol. 1.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Compression members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning
Architectural Drafting and Design (MindTap Course…
Architectural Drafting and Design (MindTap Course…
Civil Engineering
ISBN:
9781285165738
Author:
Alan Jefferis, David A. Madsen, David P. Madsen
Publisher:
Cengage Learning