An industrial load operates at 30 kW, 0.8 pf lagging. The load voltage is 220/0° V rms. The real and reactive power losses in the transmission- line feeder are 1.8 kW and 2.4 kvar, respectively. Find the magnitude of the line impedance. Select one: O a. 0.8 O b. 2.4 O c. 1.8 O d. 0.1 Oe. 3
An industrial load operates at 30 kW, 0.8 pf lagging. The load voltage is 220/0° V rms. The real and reactive power losses in the transmission- line feeder are 1.8 kW and 2.4 kvar, respectively. Find the magnitude of the line impedance. Select one: O a. 0.8 O b. 2.4 O c. 1.8 O d. 0.1 Oe. 3
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.7MCQ
Related questions
Question
![An industrial load operates at 30 kW, 0.8 pf lagging. The load voltage is 22020° V rms. The real and reactive power losses in the transmission-
line feeder are 1.8 kW and 2.4 kvar, respectively. Find the magnitude of the line impedance.
Select one:
O a. 0.8
O b. 2.4
O c. 1.8
O d. 0.1
Oe. 3](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F90d76a0d-2b8b-4826-8397-52e82910263d%2F8d0aaccd-ab2f-4068-8140-cb77482302aa%2Fxp8fva_processed.jpeg&w=3840&q=75)
Transcribed Image Text:An industrial load operates at 30 kW, 0.8 pf lagging. The load voltage is 22020° V rms. The real and reactive power losses in the transmission-
line feeder are 1.8 kW and 2.4 kvar, respectively. Find the magnitude of the line impedance.
Select one:
O a. 0.8
O b. 2.4
O c. 1.8
O d. 0.1
Oe. 3
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 5 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning