An electric utility company supplies a customer's house from the main power lines (110V) with two copper wires, each of which is 48.0m long and has a resistance of 0.158ohm per 305m Calculate the voltage at the customer's house for a load current of 100A. For this load current, calculate the power that the customer is receiving. Calculate the power lost in the copper wires.

icon
Related questions
Question
An electric utility company supplies a customer's house from the main power lines (110V) with two copper wires, each of which is 48.0m long and has a resistance of 0.158ohm per 305m.
Calculate the voltage at the customer's house for a load current of 100A.
For this load current, calculate the power that the customer is receiving.
Calculate the power lost in the copper wires.
Transcribed Image Text:An electric utility company supplies a customer's house from the main power lines (110V) with two copper wires, each of which is 48.0m long and has a resistance of 0.158ohm per 305m. Calculate the voltage at the customer's house for a load current of 100A. For this load current, calculate the power that the customer is receiving. Calculate the power lost in the copper wires.