An area of an interconnected power system has two fossil-fuel units operating on eco- nomic dispatch. The variable operating costs of these units are given by for 0 < P < 100 MW for P₁ > 100 MW C₁ = 4P₁ +0.02P S 8P₁ C₂ = 0.03Pr where P, and P₂ are in megawatts. Determine the power output of each unit, the in- cremental operating cost, and the total cost CT that minimizes Cy as the load demand Pr varies from 200 to 700 MW. Generating-unit inequalities and transmission losses are neglected. 4

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.31P: Consider two interconnected voltage sources connected by a line of impedance Z=jX, as shown in...
icon
Related questions
icon
Concept explainers
Question
11.19 An area of an interconnected power system has two fossil-fuel units operating on eco-
nomic dispatch. The variable operating costs of these units are given by
4P, +0.02P; for 0 < P, < 100 MW
C =
8P
for P, > 100 MW
hr
C2= 0.03P
hr
where P, and P2 are in megawatts. Determine the power output of each unit, the in-
cremental operating cost, and the total cost CT that minimizes CT as the load demand
PT varies from 200 to 700 MW. Generating-unit inequalities and transmission losses
are neglected.
11.20 Rework Problem 11.19 if the units are subject to the following inequality constraints:
100 < P, < 500 MW
50 < P; < 300 MW
Transcribed Image Text:11.19 An area of an interconnected power system has two fossil-fuel units operating on eco- nomic dispatch. The variable operating costs of these units are given by 4P, +0.02P; for 0 < P, < 100 MW C = 8P for P, > 100 MW hr C2= 0.03P hr where P, and P2 are in megawatts. Determine the power output of each unit, the in- cremental operating cost, and the total cost CT that minimizes CT as the load demand PT varies from 200 to 700 MW. Generating-unit inequalities and transmission losses are neglected. 11.20 Rework Problem 11.19 if the units are subject to the following inequality constraints: 100 < P, < 500 MW 50 < P; < 300 MW
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Types of Distribution in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning