Scenario 4 Consumption of P depends on V_1 Scenario 5 Consumption of P depends on V_1 Scenario 6 Max line current Scenario 7 Max line current Scenario 8 Max line current V_0 1 @ 35 COS Q AP/AV_1 V_0 135 ks 35 AP/AV_1 V_0 COS Q V_0 COS Q V_1 COS Q [KV] 36.75 [MW] [%/%] [KV] [MW] [%/%] [KV] [KV] [KV] 6.5 1 1.4 36.75 6.5 0.95 1.4 36.75 1 36.75 0.95 34 0.95 GENERAL DATA Line cable R XL [mm2] Ohms/km Ohms/km Length ated current [km] [A] 3 x 40 0.6766 0.33 22 150 Full Cable data (for info only) https://www.yifangcable.com/product/aluminium-conductors-steel-reinforced-acsr-bs-215-standard/ Sectional Stranding Strandin Approximate Sectional Sectional Nominal Area Steel & Wire g & Wire overall Diameter Area Aluminiu Breaking Area Area Weight Max. DC Resistance Current Load Rating diameter Steel Total at 20°C m mm2 mm mm mm mm2 mm2 mm2 kg/km kN Ohm/km A 25 6/2.36 1/2.36 7.08 26.24 4.38 30.62 106 9.61 1.093 126 30 6/2.59 1/2.59 7.77 31.61 5.27 36.88 128 11.45 0.9077 134 40 6/3.00 1/3.00 9 42.41 7.07 49.48 172 15.2 0.6766 161 50 6/3.35 1/3.35 10.05 52.88 8.82 61.7 214 18.35 0.5426 185 70 12/2.79 7/2.79 13.95 73.37 42.83 116.2 538 61.2 0.3936 268 100 6/4.72 7/1.57 14.15 105 13.5 118.5 394 32.7 0.2733 278

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.23P: A single-phase source has a terminal voltage V=1200volts and a currentI=1530, which leaves the...
icon
Related questions
Question

Analyse several voltage and current situations in different loading scenarios in a simplified radial (transformer to consumption) medium-voltage power system example. There are only 2 nodes in the 35 kV line – node 0 from the 110/35 kV and node 1 with one consumer.

Briefly reflect on the complexity of the calculations for known input or output voltage, as well as for fixed or voltage-dependent consumption in this simple power system model.
 

Analyse and discuss the sensitivity of the voltage drop [in % of amplitude and the degrees of phase] with respect to the current level [in %] and to the power factor.

Scenario 4
Consumption of P depends on V_1
Scenario 5
Consumption of P depends on V_1
Scenario 6
Max line current
Scenario 7
Max line current
Scenario 8
Max line current
V_0 1 @ 35
COS Q
AP/AV_1
V_0
135 ks
35 AP/AV_1
V_0
COS Q
V_0
COS Q
V_1
COS Q
[KV]
36.75
[MW]
[%/%]
[KV]
[MW]
[%/%]
[KV]
[KV]
[KV]
6.5
1
1.4
36.75
6.5
0.95
1.4
36.75
1
36.75
0.95
34
0.95
GENERAL DATA
Line cable R
XL
[mm2] Ohms/km Ohms/km
Length ated current
[km]
[A]
3 x 40 0.6766
0.33
22
150
Transcribed Image Text:Scenario 4 Consumption of P depends on V_1 Scenario 5 Consumption of P depends on V_1 Scenario 6 Max line current Scenario 7 Max line current Scenario 8 Max line current V_0 1 @ 35 COS Q AP/AV_1 V_0 135 ks 35 AP/AV_1 V_0 COS Q V_0 COS Q V_1 COS Q [KV] 36.75 [MW] [%/%] [KV] [MW] [%/%] [KV] [KV] [KV] 6.5 1 1.4 36.75 6.5 0.95 1.4 36.75 1 36.75 0.95 34 0.95 GENERAL DATA Line cable R XL [mm2] Ohms/km Ohms/km Length ated current [km] [A] 3 x 40 0.6766 0.33 22 150
Full Cable data (for info only)
https://www.yifangcable.com/product/aluminium-conductors-steel-reinforced-acsr-bs-215-standard/
Sectional
Stranding Strandin Approximate
Sectional Sectional
Nominal
Area
Steel
& Wire g & Wire overall
Diameter
Area
Aluminiu
Breaking
Area
Area Weight
Max. DC
Resistance
Current
Load
Rating
diameter
Steel
Total
at 20°C
m
mm2
mm
mm
mm
mm2
mm2
mm2
kg/km
kN
Ohm/km
A
25
6/2.36
1/2.36
7.08
26.24
4.38
30.62
106
9.61
1.093
126
30
6/2.59
1/2.59
7.77
31.61
5.27
36.88
128
11.45
0.9077
134
40
6/3.00
1/3.00
9
42.41
7.07
49.48
172
15.2
0.6766
161
50
6/3.35
1/3.35
10.05
52.88
8.82
61.7
214
18.35
0.5426
185
70
12/2.79
7/2.79
13.95
73.37
42.83
116.2
538
61.2
0.3936
268
100
6/4.72
7/1.57
14.15
105
13.5
118.5
394
32.7
0.2733
278
Transcribed Image Text:Full Cable data (for info only) https://www.yifangcable.com/product/aluminium-conductors-steel-reinforced-acsr-bs-215-standard/ Sectional Stranding Strandin Approximate Sectional Sectional Nominal Area Steel & Wire g & Wire overall Diameter Area Aluminiu Breaking Area Area Weight Max. DC Resistance Current Load Rating diameter Steel Total at 20°C m mm2 mm mm mm mm2 mm2 mm2 kg/km kN Ohm/km A 25 6/2.36 1/2.36 7.08 26.24 4.38 30.62 106 9.61 1.093 126 30 6/2.59 1/2.59 7.77 31.61 5.27 36.88 128 11.45 0.9077 134 40 6/3.00 1/3.00 9 42.41 7.07 49.48 172 15.2 0.6766 161 50 6/3.35 1/3.35 10.05 52.88 8.82 61.7 214 18.35 0.5426 185 70 12/2.79 7/2.79 13.95 73.37 42.83 116.2 538 61.2 0.3936 268 100 6/4.72 7/1.57 14.15 105 13.5 118.5 394 32.7 0.2733 278
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning