An alpha source was counted for 10 hours at a distance of 2 cm from a detector with an active face area of 500 mm2, If the resulting peak is integrated and found to have 2800 counts under the peak, what is the absolute activity of the source in Bq?
Q: Two 13.3 mg radium tubes are arranged in a line with their centers 5.5 cm apart. A weaker source is…
A: Decay constant for radium λ=0.006 day-1 mass of radium m=226.03 g/mol A=13.3 mg distance
Q: A Co-60 source gives a gamma dose rate of 120 μSv/h at 2.2 m away. At what distance (in meter) will…
A:
Q: The dosage of technetium-99m for a lung scan is 20. µCi /kg of body mass. How many millicuries of…
A: Given the dosage of technetium-99m for a lung scan is 20. µCi /kg of body mass. - How many…
Q: A point source of radioactive material produces a dose rate of 100 Gy/hr at 1 meter from the source.…
A:
Q: How many Gy of exposure is needed to give a canceroustumor a dose of 40 Sv if it is exposed to α…
A:
Q: . A Geiger counter measures background radiation and records 950 counts in 10 minutes. Then the…
A:
Q: 12. A point source of 5-MeV y-rays with intensity 3 x 103 y-rays/cm2- sec is shielded with 50 cm of…
A: Given: The energy of the Gamma-rays is E = 5 MeV The intensity of the point source is I0 = 3 x 103…
Q: radiation worker stands 50 cm away from a radioactive source of 25 mCi 57Co. Calculate the…
A: Given the activity of the radioactive source is equal to 25 mCi . The half- life of the source is…
Q: The manufacturer of a smoke alarm decides that the smallestcurrent of α radiation he can detect is…
A:
Q: A radioactive contaminant gives an unfortunate 0.5 kg lab rat a dose of 1500 rem in just 1 minute.…
A:
Q: 14C, the background counting rate for a single blank of a given sample composition was determined to…
A: Given Background counting rate for a sample composition Rb = 25 cpm for tb= 30 min…
Q: CSDA range Determine the expected range of 2 MeV beta radiation in polyethylene, Aluminium and air.…
A: Collision stopping power is the average rate of energy loss per unit path length caused by Coulomb…
Q: Pions implanted into undoped Si have a Gaussian profile with a peak dopant concentration of…
A:
Q: An x-ray technician works 5 days per week, 50 weeks per year. (Assume that the technician takes an…
A: Given data: Working rate = 5 days/week Per year working rate = 50 weeks/yr Number of per day taken…
Q: A certain biological sample is given a dose of 7.50 rad from alpha particles. (WR = 20) Calculate…
A: Given :- a dose of 7.50 rad from alpha particles WR = 20 Equivalent dose HT = absorbed dose * WR =…
Q: A radioactive source is producing 1.50 MeV gamma rays. If two detectors are placed 4.00 m and 7.00 m…
A: Distance of two detecters from the source…
Q: A worker will need to conduct a repair to a pipe containing radioactive waste. The pipe is 10 m…
A: Part (a): Given that the distance of the worker from the radiation pipe is 50 cm, the radiation dose…
Q: Calculate the fraction per square mm area of 7.7MeV alpha particle scattered at 45degrees from a…
A: Solution attached in the photo.......
Q: 71 A 20 mCi gamma source emits 0.200 Mev photons 65% of the time and 0.750 Mey photons 35% of the…
A:
Q: A synthetic radioisotope is freshly prepared in a lab that has an activity of 10.0 mCi. If the…
A:
Q: A solution of In-111 DTPA from the Amersham Corp. in Great Britain arrives in your department with…
A: The half-life of In-111 according to the chart of nuclides is…
Q: Calculate the current produced when alpha particles (10 MeV) pass through a gas in ionization…
A: rate of particles = 600 particles / h = 600 /3600 particles/ second = 1/6 particles/ second We…
Q: Estimate the average range of 1.31 MeV alpha particles striking an aluminum slab parallel to its…
A: The given information in the question is: The energy of the alpha particles: 1.31 MeV The density…
Q: A cancerous tumour is exposed to an a-emitter with an RBE of 16. What absorbed dose, in Gy, is…
A: RBE of 16. 64 Sv
Q: If you were to use a collimator with a shielding factor of 20 for a RED (radiation exposure device)…
A: if we were to Use A Collimator With A Shielding Factor Of 20 For A RED (radiation Exposure Device)…
Q: A 228Th source is labeled 1.50 mCi, but its present activity is found to be 3.47 ✕ 106 Bq. (a)What…
A:
Q: A 7. A saline solution of 24Na with an activity of 300 kBq is injected into the bloodstream of one…
A: The objective of the question is to calculate the patient's blood volume using the given activity of…
Q: A sample contains 1.0 GBq of ⁹0 Sr and 0.62 GBq of ⁹0Y. (a) What will be the total activity of the…
A:
Q: (Internal Exposure: Internal Radiation Dose) Given a 20µCi of 32P (T/2 = 14.3 days) is delivered…
A: GIven: 20μCi of P32 Half time, t12=14.3 days 70 kg Biological half-life, 19 days…
Q: technetium half life is 4.8 hours. If a patient receicves a dose with an activity of 35.9 mCi of…
A: Half life of technetium (t1/2) = 4.8 hours Initial activity (Ao) = 35.9 mCi
Q: A technique of 40 mAs , 200 kV, 200 cm SID produces 0.12 Gy exposure. If we change the technique to:…
A:
Q: The small intestine has a mucus layer approximately 200 um thick. A worker accidentally ingests a…
A: It is observed that a 5.5 MeV alpha particle can be stopped by a 40 um thick human tissue. In the…
Step by step
Solved in 2 steps with 2 images