Air pressure in a tank is measured and the related digital value is transmitted to the control room using signed two's complement form along with an even parity scheme. Tank's digital air pressure value is considered a binary number that varies between (-3) bar to (+3) bar. The received binary number along with the parity is checked in control room. If there is a negative pressure then a yellow LED should turn on to indicate the low pressure. If the tanks pressure is above (+1) bar a green LED should turn on to indicate an acceptable pressure. If the parity shows that a wrong value is received then a red LED should turn on indicating a transmission error. - Give a truth table that will define the outputs for three LEDs. - Write the simplest expression you can for all LEDs. - Draw a circuit to implement your design.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Air pressure in a tank is measured and the related digital value is
transmitted to the control room using signed two's complement form along with an even
parity scheme. Tank's digital air pressure value is considered a binary number that varies
between (-3) bar to (+3) bar. The received binary number along with the parity is checked
in control room. If there is a negative pressure then a yellow LED should turn on to indicate
the low pressure. If the tanks pressure is above (+1) bar a green LED should turn on to
indicate an acceptable pressure. If the parity shows that a wrong value is received then a
red LED should turn on indicating a transmission error.
- Give a truth table that will define the outputs for three LEDs.
- Write the simplest expression you can for all LEDs.
- Draw a circuit to implement your design.
Transcribed Image Text:Air pressure in a tank is measured and the related digital value is transmitted to the control room using signed two's complement form along with an even parity scheme. Tank's digital air pressure value is considered a binary number that varies between (-3) bar to (+3) bar. The received binary number along with the parity is checked in control room. If there is a negative pressure then a yellow LED should turn on to indicate the low pressure. If the tanks pressure is above (+1) bar a green LED should turn on to indicate an acceptable pressure. If the parity shows that a wrong value is received then a red LED should turn on indicating a transmission error. - Give a truth table that will define the outputs for three LEDs. - Write the simplest expression you can for all LEDs. - Draw a circuit to implement your design.
Expert Solution
steps

Step by step

Solved in 1 steps with 1 images

Blurred answer
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,