A three-phase transmission line is feeding from a 400-MVA, 240/24 kV transformer at its sending end. The line has an impedance of 0.6 + jl.20 per phase while the transformer has an equivalent impedance of 1.2 + jl.6 Q referred to the HV side. If the base to be used is 100 MVA, 20 kV for the transmission line, find the per-unit values to be used for the transformer and line impedances A single-phase transformer is rated 15 MVA, 66/11.5 kV. With the 11.5 kV winding short-circuited, rated current flows when the applied voltage to the primary is 5.5 kv. The power input is read as 100 kW. Determine the per unit equivalent impedance of the transformer.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A three-phase transmission line is feeding from a 400-MVA, 240/24 kV transformer at
its sending end. The line has an impedance of 0.6 + jl.20 per phase while the
transformer has an equivalent impedance of 1.2 + jl.6 Q referred to the HV side. If
the base to be used is 100 MVA, 20 kV for the transmission line, find the per-unit values
to be used for the transformer and line impedances
A single-phase transformer is rated 15 MVA, 66/11.5 kV. With the 11.5 kV winding
short-circuited, rated current flows when the applied voltage to the primary is 5.5 kv.
The power input is read as 100 kW. Determine the per unit equivalent impedance of
the transformer.
Transcribed Image Text:A three-phase transmission line is feeding from a 400-MVA, 240/24 kV transformer at its sending end. The line has an impedance of 0.6 + jl.20 per phase while the transformer has an equivalent impedance of 1.2 + jl.6 Q referred to the HV side. If the base to be used is 100 MVA, 20 kV for the transmission line, find the per-unit values to be used for the transformer and line impedances A single-phase transformer is rated 15 MVA, 66/11.5 kV. With the 11.5 kV winding short-circuited, rated current flows when the applied voltage to the primary is 5.5 kv. The power input is read as 100 kW. Determine the per unit equivalent impedance of the transformer.
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,