A- what information can be obtained from the open-circuit test. B- the in nstnume

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
None
A- what information can be obtained from the open-circuit test.
B- the instrument readings obtained from open and short-circuit tests on 10KVA, 450/120V,
SOHZ transformer are:
O.C. test: V = 120V; I=4.2A; W- 80W; W, and I, were read on the low-voltage side.
S.C. test: V, = 8.5V; I = 18A; W, 100W with low voltage winding short-circuited compute:
1- the equivalent circuit constants referred to high voltage side.
2- efficiency and voltage regulation for full-load at 0.8 P.F. lagging.
3- the voltage to be applied to the high voltage side on full-load at 0.8 power factor lag when the
secondary load voltage is 120V.
4- if the transformer terminals are short circuited accidently when working at normal voltage;
calculate the approximate value of the short circuit current in secondary winding.
5- calculate the maximum regulation at full-load.
Transcribed Image Text:A- what information can be obtained from the open-circuit test. B- the instrument readings obtained from open and short-circuit tests on 10KVA, 450/120V, SOHZ transformer are: O.C. test: V = 120V; I=4.2A; W- 80W; W, and I, were read on the low-voltage side. S.C. test: V, = 8.5V; I = 18A; W, 100W with low voltage winding short-circuited compute: 1- the equivalent circuit constants referred to high voltage side. 2- efficiency and voltage regulation for full-load at 0.8 P.F. lagging. 3- the voltage to be applied to the high voltage side on full-load at 0.8 power factor lag when the secondary load voltage is 120V. 4- if the transformer terminals are short circuited accidently when working at normal voltage; calculate the approximate value of the short circuit current in secondary winding. 5- calculate the maximum regulation at full-load.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
KVL and KCL
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,