A wastewater treatment plant (WWTP) discharges its effluent in a river. The regulatory agency wishes to ensure that the DO level five (5) kilometres downstream and beyond from the WWTP is at least equal to 4.2 mg/L. Use the information provided in Table 1.1 to assist the agency in its environmental management. Table 1.1 Parameter values under current conditions Value Parameter Water temperature (°C) Effluent flow from the WWTP (m³/d) River flow upstream of plant (m/s) DOsat at 25°C (mg/L) DO in effluent from the WWTP (mg/L) DO upstream WWTP (mg/L) ka at 20 °C (d) k, at 20°C (d) River velocity, v (m/s) Ultimate BOD in river upstream WWTP, Lo(mg/L) Ultimate BOD in effluent from WWTP, Lo (mg/L) 25.0 17360 0.43 8.38 1.0 6.5 0.458 0.478 0.10 0.0 15.0 a. Compute the DO and the initial ultimate BOD after mixing. b. Compute the initial DO deficit after the effluent mixes with the river. c. Compute the DO concentration five (5) kilometres downstream from the WWTP. d. Determine whether or not the WWTP treatment level satisfies the requirements of the regulatory agency.
A wastewater treatment plant (WWTP) discharges its effluent in a river. The regulatory agency wishes to ensure that the DO level five (5) kilometres downstream and beyond from the WWTP is at least equal to 4.2 mg/L. Use the information provided in Table 1.1 to assist the agency in its environmental management. Table 1.1 Parameter values under current conditions Value Parameter Water temperature (°C) Effluent flow from the WWTP (m³/d) River flow upstream of plant (m/s) DOsat at 25°C (mg/L) DO in effluent from the WWTP (mg/L) DO upstream WWTP (mg/L) ka at 20 °C (d) k, at 20°C (d) River velocity, v (m/s) Ultimate BOD in river upstream WWTP, Lo(mg/L) Ultimate BOD in effluent from WWTP, Lo (mg/L) 25.0 17360 0.43 8.38 1.0 6.5 0.458 0.478 0.10 0.0 15.0 a. Compute the DO and the initial ultimate BOD after mixing. b. Compute the initial DO deficit after the effluent mixes with the river. c. Compute the DO concentration five (5) kilometres downstream from the WWTP. d. Determine whether or not the WWTP treatment level satisfies the requirements of the regulatory agency.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning