3. Sewage with a fecal coliform bacteria count of 8x 10° CFUS / 100 mL is leaking into a river at a rate of 0.1 m/s. Upstream of the leak, the river flow is 100 m/s and the fecal coliform bacteria count is 40 CFUS / 100 ml. The average velocity in the river is given as 0.25 m /s and the bacteria die-off rate is given as 2.4 /d. a. Write the mass balance equation for fecal coliform bacteria at the discharge point of the and downstream of the discharge. • See pdf O Not sure how to proceed b. Determine the fecal coliform concentration at a public beach 10 km downstream of the leak. CFUS / 100 ml e Will the New York State fecal coliform bathing standard of 200 CFUS /100 ml be met? O Yes O No Check

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
3. Sewage with a fecal coliform bacteria count of 8x105 CFUS / 100 mL is leaking into a river at a rate of 0.1 m/s. Upstream of the leak, the river flow is 100 m/s and the fecal coliform bacteria count is 40 CFUS / 100 mL. The average velocity in the river is given as 0.25 m /s and the bacteria die-off rate is given as
2.4 /d.
a. Write the mass balance equation for fecal coliform bacteria at the discharge point of the and downstream of the discharge.
O See pdf
O Not sure how to proceed
b. Determine the fecal coliform concentration at a public beach 10 km downstream of the leak.
CFUS / 100 mL
c. Will the New York State fecal coliform bathing standard of 200 CFUS /100 mL be met?
O Yes
O No
Check
Transcribed Image Text:3. Sewage with a fecal coliform bacteria count of 8x105 CFUS / 100 mL is leaking into a river at a rate of 0.1 m/s. Upstream of the leak, the river flow is 100 m/s and the fecal coliform bacteria count is 40 CFUS / 100 mL. The average velocity in the river is given as 0.25 m /s and the bacteria die-off rate is given as 2.4 /d. a. Write the mass balance equation for fecal coliform bacteria at the discharge point of the and downstream of the discharge. O See pdf O Not sure how to proceed b. Determine the fecal coliform concentration at a public beach 10 km downstream of the leak. CFUS / 100 mL c. Will the New York State fecal coliform bathing standard of 200 CFUS /100 mL be met? O Yes O No Check
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Storm sewers and detention
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning