A venturi meter with a 50 mm throat is used to measure a flow of slightly salt water in a pipe of inside diameter 100 mm. The meter is checked by adding 20 cm³/s of normal sodium chloride solution above the meter and analysing a sample of water downstream from the meter. Before addition of the salt, 1000 cm³ of water requires 10 cm³ of 0.1 M silver nitrate solution in a titration. 1000 cm³ of the downstream sample required 23.5 cm³ of 0.1 M silver nitrate. If a mercury-under-water manometer connected to the meter gives a reading of 221 mm, what is the discharge coefficient of the meter? Assume that the density of the liquid is not appreciably affected by the salt.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

Please help me 

A venturi meter with a 50 mm throat is used to measure a flow of slightly salt water in
a pipe of inside diameter 100 mm. The meter is checked by adding 20 cm³/s of normal
sodium chloride solution above the meter and analysing a sample of water downstream
from the meter. Before addition of the salt, 1000 cm³ of water requires 10 cm³ of 0.1 M
silver nitrate solution in a titration. 1000 cm³ of the downstream sample required 23.5 cm³
of 0.1 M silver nitrate. If a mercury-under-water manometer connected to the meter gives
a reading of 221 mm, what is the discharge coefficient of the meter? Assume that the
density of the liquid is not appreciably affected by the salt.
Transcribed Image Text:A venturi meter with a 50 mm throat is used to measure a flow of slightly salt water in a pipe of inside diameter 100 mm. The meter is checked by adding 20 cm³/s of normal sodium chloride solution above the meter and analysing a sample of water downstream from the meter. Before addition of the salt, 1000 cm³ of water requires 10 cm³ of 0.1 M silver nitrate solution in a titration. 1000 cm³ of the downstream sample required 23.5 cm³ of 0.1 M silver nitrate. If a mercury-under-water manometer connected to the meter gives a reading of 221 mm, what is the discharge coefficient of the meter? Assume that the density of the liquid is not appreciably affected by the salt.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The