A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent series impedance 62 + j388 mΩ referred to the low-voltage winding. a. A three-phase short circuit is applied to the low-voltage winding. Calculate the voltage applied to the high-voltage winding which will result in rated current into the short circuit. b. The short circuit is removed and a three-phase load is connected to the low-voltage winding. With

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

3. A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase
equivalent series impedance 62 + j388 mΩ referred to the low-voltage winding.
a. A three-phase short circuit is applied to the low-voltage winding. Calculate the voltage applied to the
high-voltage winding which will result in rated current into the short circuit.
b. The short circuit is removed and a three-phase load is connected to the low-voltage winding. With
rated voltage applied to the high-voltage winding, the input power to the transformer is observed to
be 18 MW at 0.75 power-factor lagging. Calculate the line-line terminal voltage at the load.

3. A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase
equivalent series impedance 62 + j388 m2 referred to the low-voltage winding.
a. A three-phase short circuit is applied to the low-voltage winding. Calculate the voltage applied to the
high-voltage winding which will result in rated current into the short circuit.
b. The short circuit is removed and a three-phase load is connected to the low-voltage winding. With
rated voltage applied to the high-voltage winding, the input power to the transformer is observed to
be 18 MW at 0.75 power-factor lagging. Calculate the line-line terminal voltage at the load.
Transcribed Image Text:3. A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent series impedance 62 + j388 m2 referred to the low-voltage winding. a. A three-phase short circuit is applied to the low-voltage winding. Calculate the voltage applied to the high-voltage winding which will result in rated current into the short circuit. b. The short circuit is removed and a three-phase load is connected to the low-voltage winding. With rated voltage applied to the high-voltage winding, the input power to the transformer is observed to be 18 MW at 0.75 power-factor lagging. Calculate the line-line terminal voltage at the load.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,