A three phase 390 volt (line voltage) distribution system feeds power to a household load. Each phase of the system (distribution line) has an impedance consisting of a resistance (0.60) and a reactance (0.40) (inductive). The system is connected to three-phase load with an impedance of j +62 in a delta connection. What is the active, reactive and apparent power of the load (notice that distribution line impedance is not part of the load)? Give the answers to two decimal places. a) Absolute value of current feeded by the voltage source. I = 3.62 A Your last answer was interpreted as follows: 3.62 b) Active power P = c) Reactive power Q d) Apparent power S (absolute value) = = kVA kW kV Ar 4

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A three phase 390 volt (line voltage) distribution system feeds power to
a household load. Each phase of the system (distribution line) has an
impedance consisting of a resistance (0.602) and a reactance (0.40)
(inductive). The system is connected to three-phase load with an
impedance of j +62 in a delta connection. What is the active, reactive
and apparent power of the load (notice that distribution line
impedance is not part of the load)? Give the answers to two decimal
places.
a) Absolute value of current feeded by the voltage source. I =
3.62
A
Your last answer was interpreted as follows: 3.62
b) Active power P =
c) Reactive power Q =
d) Apparent power S (absolute value)
kVA
=
kW
kV Ar
4
Transcribed Image Text:A three phase 390 volt (line voltage) distribution system feeds power to a household load. Each phase of the system (distribution line) has an impedance consisting of a resistance (0.602) and a reactance (0.40) (inductive). The system is connected to three-phase load with an impedance of j +62 in a delta connection. What is the active, reactive and apparent power of the load (notice that distribution line impedance is not part of the load)? Give the answers to two decimal places. a) Absolute value of current feeded by the voltage source. I = 3.62 A Your last answer was interpreted as follows: 3.62 b) Active power P = c) Reactive power Q = d) Apparent power S (absolute value) kVA = kW kV Ar 4
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Sinusoids and Phasors of Alternating Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,