A step-down chopper is to be used to supply power from a 600-V overhead wire to the commutator motor on a trolley bus. The motor may be mod- eled as a generated direct voltage in series with a resistance of 0.2 and an inductance of 25 mH. The frequency of the chopper is set at 500 Hz. (a) When the bus is stopped, what should be the ON time of the chopper to provide a motor current of 150 A? (b) What is the maximum possible generated voltage of the motor for which a current of 150 A can be supplied? (c) What is the average value of the supply current for the conditions of (a) and (b)? (d) If the motor current is to be continuous, what should be its minimum value?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A step-down chopper is to be used to supply power from a 600-V overhead
wire to the commutator motor on a trolley bus. The motor may be mod-
eled as a generated direct voltage in series with a resistance of 0.2 and
an inductance of 25 mH. The frequency of the chopper is set at 500 Hz.
(a) When the bus is stopped, what should be the ON time of the chopper
to provide a motor current of 150 A?
(b) What is the maximum possible generated voltage of the motor for
which a current of 150 A can be supplied?
(c) What is the average value of the supply current for the conditions of
(a) and (b)?
បទៅនឹងរស់របស
(d) If the motor current is to be continuous, what should be its minimum.
value?
Transcribed Image Text:A step-down chopper is to be used to supply power from a 600-V overhead wire to the commutator motor on a trolley bus. The motor may be mod- eled as a generated direct voltage in series with a resistance of 0.2 and an inductance of 25 mH. The frequency of the chopper is set at 500 Hz. (a) When the bus is stopped, what should be the ON time of the chopper to provide a motor current of 150 A? (b) What is the maximum possible generated voltage of the motor for which a current of 150 A can be supplied? (c) What is the average value of the supply current for the conditions of (a) and (b)? បទៅនឹងរស់របស (d) If the motor current is to be continuous, what should be its minimum. value?
Expert Solution
steps

Step by step

Solved in 6 steps with 18 images

Blurred answer
Knowledge Booster
Single Phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,