A plug flow reactor has a flow rate of 50 gal/min and the inlet concentration of a contaminant. A. is 300 mg/L and the outlet concentration is 9 mg/L. Assuming that the reaction kinetics are 1st order, and the rate constant, k-1.0 hr¹, determine the following: a) What is the volume of the PFR reactor (gal)? b) What would the outlet concentration (mg/L) be for a DPFR with d-0.5, if the PFR were replaced with a DPFR that has the same volume as the PFR in a)? c) What would the outlet concentration (mg/L) be for 3-CFSTRs in series, if the PFR were replaced with 3-CFSTRS in series with the same total volume as the PFR in a)?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
lem. A plug flow reactor has a flow rate of 50 gal/min and the inlet concentration of
a contaminant, A. is 300 mg/L and the outlet concentration is 9 mg/L. Assuming that the
reaction kinetics are 1st order, and the rate constant, k-1.0 hr¹, determine the following:
a) What is the volume of the PFR reactor (gal)?
b) What would the outlet concentration (mg/L) be for a DPFR with d-0.5, if the PFR were
replaced with a DPFR that has the same volume as the PFR in a)?
c) What would the outlet concentration (mg/L) be for 3-CFSTRs in series, if the PFR were
replaced with 3-CFSTRS in series with the same total volume as the PFR in a)?
Transcribed Image Text:lem. A plug flow reactor has a flow rate of 50 gal/min and the inlet concentration of a contaminant, A. is 300 mg/L and the outlet concentration is 9 mg/L. Assuming that the reaction kinetics are 1st order, and the rate constant, k-1.0 hr¹, determine the following: a) What is the volume of the PFR reactor (gal)? b) What would the outlet concentration (mg/L) be for a DPFR with d-0.5, if the PFR were replaced with a DPFR that has the same volume as the PFR in a)? c) What would the outlet concentration (mg/L) be for 3-CFSTRs in series, if the PFR were replaced with 3-CFSTRS in series with the same total volume as the PFR in a)?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The