a - pipette 10.00 mL of 0.100 M CaCl2 stock into 100 ml volumetric flask b - in 100 ml volumetric flask prepare a 1:10 dilution C - 1:10 dilution in 100 ml flask d - pipette 5.00 mL in 100 ml volumetric flask This is your experimental data for Experiment #8, Determination of Ca in a Supplement by Ion Selective Electrode. YOU MUST READ THE EXPERIMENTAL WRITE-UP AND COMPLETE THE PRE-LAB PRIOR TO DOWNLOADING THIS DATA!! Your unknown number is: 804 Your sample weighed 1.2860 grams You follow the procedure making up your unknown. You made your standards, and when you measured them on the ISE meter produced the following data: Standard A has a meter reading of -27.20 mv Standard B has a meter reading of -56.11 mv Standard C has a meter reading of -85.69 mv Standard D has a meter reading of -95.03 mv The unknown has a meter reading of -87.56 mv Produce and submit a spreadsheet with a PROPERLY LABELLED calibration curve graph with a linear least square calculation of the best fit line. Calculate the following in CLEARLY LABELLED cells in your spreadsheet. The slope = 15.138 The intercept = 29.21 The R2 value = The total amount of Ca in the unknown you were given at the start of the experiment = The wt% of Ca in the unknown = 6.195 mg

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question

2

 

a - pipette 10.00 mL of 0.100 M CaCl2 stock into
100 ml volumetric flask
b - in 100 ml volumetric flask prepare a 1:10
dilution
C - 1:10 dilution in 100 ml flask
d - pipette 5.00 mL in 100 ml volumetric flask
This is your experimental data for Experiment # 8, Determination of Ca in a Supplement by Ion Selective Electrode.
YOU MUST READ THE EXPERIMENTAL WRITE-UP AND COMPLETE THE PRE-LAB PRIOR TO DOWNLOADING THIS DATA!!
Your unknown number is: 804
Your sample weighed 1.2860 grams
You follow the procedure making up your unknown.
You made your standards, and when you measured them on the ISE meter produced the following data:
Standard A has a meter reading of -27.20 mv
Standard B has a meter reading of -56.11 mv
Standard C has a meter reading of -85.69 mv
Standard D has a meter reading of -95.03 mv
The unknown has a meter reading of -87.56 mv
Produce and submit a spreadsheet with a PROPERLY LABELLED calibration curve graph with a linear least square calculation of the best fit line.
Calculate the following in CLEARLY LABELLED cells in your spreadsheet.
The slope = 15.138
The intercept = 29.21
The R2 value =
The total amount of Ca in the unknown you were given at the start of the experiment =
mg
The wt% of Ca in the unknown = 6.195
X %
Transcribed Image Text:a - pipette 10.00 mL of 0.100 M CaCl2 stock into 100 ml volumetric flask b - in 100 ml volumetric flask prepare a 1:10 dilution C - 1:10 dilution in 100 ml flask d - pipette 5.00 mL in 100 ml volumetric flask This is your experimental data for Experiment # 8, Determination of Ca in a Supplement by Ion Selective Electrode. YOU MUST READ THE EXPERIMENTAL WRITE-UP AND COMPLETE THE PRE-LAB PRIOR TO DOWNLOADING THIS DATA!! Your unknown number is: 804 Your sample weighed 1.2860 grams You follow the procedure making up your unknown. You made your standards, and when you measured them on the ISE meter produced the following data: Standard A has a meter reading of -27.20 mv Standard B has a meter reading of -56.11 mv Standard C has a meter reading of -85.69 mv Standard D has a meter reading of -95.03 mv The unknown has a meter reading of -87.56 mv Produce and submit a spreadsheet with a PROPERLY LABELLED calibration curve graph with a linear least square calculation of the best fit line. Calculate the following in CLEARLY LABELLED cells in your spreadsheet. The slope = 15.138 The intercept = 29.21 The R2 value = The total amount of Ca in the unknown you were given at the start of the experiment = mg The wt% of Ca in the unknown = 6.195 X %
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Electroanalytical Techniques
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY