A new water supply main is being planned for a new city of 2 million population and average per capita water demand of 300 litres per day. The water source is located 50 km from the newly planned city at similar elevation as the city. Water is proposed to be conveyed using two number of 100 cm diameter cast iron pipeline. Assume water density of 1,000 kg/m3 and viscosity of 1.0 x 10-5 kg/m-s. Determine the following: a. The total head loss (in m) during this conveyance of water in each pipeline. Use Colebrook equation to calculate frictional factor. b. The total electrical power (in MW for both pipeline) required to pump this water over 50 km distance assuming combined pump-motor efficiency of 70%. c. If the maximum pressure allowed in the pipeline is 1 MPa, how many pump stations (minimum numbers) are required along the 50 km distance pipeline instead of just one large pump. d. If the two pipes are replaced by just one pipe, what should be the minimum diameter of the pipe under similar pumping power (mm) requirements

Sustainable Energy
2nd Edition
ISBN:9781337551663
Author:DUNLAP, Richard A.
Publisher:DUNLAP, Richard A.
Chapter14: Ocean Thermal Energy Conversion And Ocean Salinity Gradient Energy
Section: Chapter Questions
Problem 14P
icon
Related questions
Question
100%

A new water supply main is being planned for a new city of 2 million population and average per capita water demand of 300 litres per day. The water source is located 50 km from the newly planned city at similar elevation as the city. Water is proposed to be conveyed using two number of 100 cm diameter cast iron pipeline. Assume water density of 1,000 kg/m3 and viscosity of 1.0 x 10-5 kg/m-s. Determine the following:


a. The total head loss (in m) during this conveyance of water in each pipeline. Use Colebrook equation to calculate frictional factor.

b. The total electrical power (in MW for both pipeline) required to pump this water over 50 km distance assuming combined pump-motor efficiency of 70%.

c. If the maximum pressure allowed in the pipeline is 1 MPa, how many pump stations (minimum numbers) are required along the 50 km distance pipeline instead of just one large pump.

d. If the two pipes are replaced by just one pipe, what should be the minimum diameter of the pipe under similar pumping power (mm) requirements

Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Highway drainage
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Fundamentals of Geotechnical Engineering (MindTap…
Fundamentals of Geotechnical Engineering (MindTap…
Civil Engineering
ISBN:
9781305635180
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Principles of Geotechnical Engineering (MindTap C…
Principles of Geotechnical Engineering (MindTap C…
Civil Engineering
ISBN:
9781305970939
Author:
Braja M. Das, Khaled Sobhan
Publisher:
Cengage Learning
Engineering Fundamentals: An Introduction to Engi…
Engineering Fundamentals: An Introduction to Engi…
Civil Engineering
ISBN:
9781305084766
Author:
Saeed Moaveni
Publisher:
Cengage Learning
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781305081550
Author:
Braja M. Das
Publisher:
Cengage Learning
Solid Waste Engineering
Solid Waste Engineering
Civil Engineering
ISBN:
9781305635203
Author:
Worrell, William A.
Publisher:
Cengage Learning,