A motor is required for an industrial air extraction system. The fan speed should be constant between 0 rpm and 2900 rpm, say two speeds. The maximum torque to nominal torque ratio should be no more than 4.0, the torque rating should be at around 100 Nm. The power factor should not be lower than 0.8 for power factor correction reasons. A 100A miniature circuit breaker (MCB) will be used to protect the motor. The enclosure should meet IP55 standard, and the feet are to be bolted to the stator and made of cast iron. From the ABB motors data sheet link attached select a suitable motor, giving the motor type number.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

A motor is required for an industrial air extraction system.

The fan speed should be constant between 0 rpm and 2900 rpm, say two speeds.

The maximum torque to nominal torque ratio should be no more than 4.0, the torque rating should be at around 100 Nm. The power factor should not be lower than 0.8 for power factor correction reasons.
A 100A miniature circuit breaker (MCB) will be used to protect the motor.

The enclosure should meet IP55 standard, and the feet are to be bolted to the stator and made of cast iron. From the ABB motors data sheet link attached select a suitable motor, giving the motor type number.

 

 

https://library.e.abb.com/public/7b37518ea1d0cb94c1257b130056f26d/General%20performance%20motors%20EN%2002_2010.pdf

General performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
IE1 efficiency class according to IEC 60034-30; 2008
Efficiency
IEC 60034-2-1; 2007
Full 3/4 1/2
Speed load load
r/min 100% 75% 50%
400 V 50 Hz
69.2
Product code
Torque
TN
T₁
T
Output
kW
Nm Ty
TN TN
CENELEC-design
0.96 3.9 1.3 2.2 2.3 0.00039
73.5 73.7 0.80
77.3 79.3
0.85
77.9 0.81
79.1
Motor type
3000 r/min = 2-poles
0.37 M2BA 71 A
0.55 M2BA 71 B
0.75
M2BA 80 A
M2BA 80 B
M2BA 90 S
M2BA 90 L
M2BA 100 L
M2BA 112 M
81.2
2.7 2.8 0.00101
u
1.1
1.5
2.2
82.5
3GBA 091 102-B
2875
83.4
63
2.3 2.4 0.00254 24
2.7 3.2 0.00445 32
3
3GBA 101 101- B
2910
65
4
3GBA 111 101- B
2880
37
67
61
75
5.5
7.5
11
15
18.5
22
30
68 73
118 73
132 73
140 73
167 75
213 75
239 75
296 75
338 75
37
45
1.27 4.3 1.95 2.4 2.49 0.00051
1.71 5.9 2.5 2.3 2.7 0.0008
81.2 0.82 2.4 5.7 3.7
80.3 0.81 3.2 7.2 4.9
84.5 83.5 0.84 4.5 6.6 7.3
83.2 83.4 81.4 0.83 6.2 7.0 9.8
84.9 86.2 85.9 0.89 7.6 7.5 13.2 2.4 2.6 0.00531
3GBA 131 101- B 2885 85.4 85.0 83.0 0.82 11.3 6.6 18.2 2.3 3.35 0.01029
3GBA 131 102-B 2890 86.5 86.3 84.3 0.81 15.4 7.6 24.7 2.7 3.5 0.01275
3GBA 161 041- G 2921 88.2 89.0 88.1 0.89 20.2 6.3 35.9 1.7 2.7 0.038
3GBA 161 042-G 2929 89.3 90.2 89.3 0.90 26.9 7.1 48.9 2.2 3.1 0.048
3GBA 161 043-G 2935 89.8 90.1 89.4 0.91 32.6 7.2 60.1 2.2 3.2 0.054
3GBA 181 041-G 2928 90.4 90.6 89.6
0.90 39 7.1 71.7 2.8 3.1 0.059
3GBA 201 041- G 2948 91.1 91.1 89.8 0.88 54 7.7 97.1 2.8 3.6 0.093
3GBA 201 042-G 2949 91.6 92.0 91.6 0.92 63.3 7.7 119 2.5 3.4 0.118
3GBA 221 041- G 2948 92.1 92.3 91.8
0.91 77.4 7.7 145 2.7 2.9 0.198
3GBA 251 041- G 2964 92.4 92.4 91.5 0.91 94.4 7.3 177 2.3 2.3 0.281
400 V 50 Hz
CENELEC-design
0.81 0.65 3.5 1.74
0.83 0.88 4.0
4.0 2.5
73.8 70.0 0.73 1.45 5.0 3.7
77.0 77.0 73.7 0.72 1.95 5.0 5.0
78.4 79.6 78.4 0.79 2.5 4.8 7.4 1.9 2.3 0.0033
80.4 81.4 80.0 0.78 3.4 5.4 10.1 2.5 3.2 0.0044
83.2 84.3 83.5 0.80 4.7 5.4 14.7 2.1 2.8 0.00873 34
83.2 84.1 83.2 0.80 6.5 6.2 20.0 2.2 2.8 0.009
83.8 85.2 85.1 0.82 8.4 6.2 26.8 2.2 2.7 0.0106 39
87.8 87.8 85.9 0.76 11.8 6.0 35.9 1.8 2.7 0.02635 60
86.7 88.0 88.0 0.80 15.6 5.7 49.5 1.9 2.4 0.03282 70
89.0 88.4 0.81 22.2 6.5 71.9 2.3 2.6 0.068
120
3GBA 162 042-G
89.8 89.2 0.82 29.6 7.1 97.9 2.6 3.3 0.085
3GBA 182 041- G 1465 89.8 90.3 89.8 0.82 36.2 7.7 120 2.6 3.1 0.103
3GBA 182 042-G 1463 90.4 90.9 90.5 0.83 42.3 7.7 143 2.9 3.5 0.122
3GBA 202 041- G 1475 91.1 91.5 91.0 0.83 57.2 7.3 194 2.4 3.0 0.22
3GBA 222 041- G 1477 91.6 91.9 91.4 0.84 69.4 6.9 239
3GBA 222 042-G 1478 92.1 92.4 91.9 0.84 83.9 7.4 290
55 M2BA 250 SMA 3GBA 252 041- G 1478 92.4 92.7 92.2 0.85 101 7.4 355
The two bullets in the product code indicate choice of mounting
3GBA 072 101-B
3GBA 072 102-..B
1365 68.3
1380 72.4
74.5
70.8 69.7
74.5 74.6
3GBA 082 101-B
1415
M2BA 132 SA
M2BA 132 SB
M2BA 160 MLA
M2BA 160 MLB
M2BA 160 MLC
M2BA 180 MLA
M2BA 200 MLA
M2BA 200 MLB
M2BA 225 SMA
55
M2BA 250 SMA
1500 r/min 4-poles
0.25 M2BA 71 A
0.37 M2BA 71 B
0.55 M2BA 80 A
0.75 M2BA 80 B
1.1 M2BA 90 S
M2BA 90 L
M2BA 100 LA
M2BA 100 LB
M2BA 112 M
M2BA 132 S
M2BA 132 M
M2BA 160 MLA
M2BA 160 MLB
M2BA 180 MLA
M2BA 180 MLB
M2BA 200 MLA
M2BA 225 SMA
M2BA 225 SMB
1.9 2.6 0.00198
16
50
22
50
1.5
25
50
3GBA 082 102-B 1410
3GBA 092 101-B 1410
3GBA 092 102-B 1410
3GBA 102 101-B 1425
3GBA 102 102-B 1430
3GBA 112 101-B 1420
64
2.2
3
35
67
60
66
4
5.5
7.5
11
15
18.5
22
3GBA 132 101-B 1460
3GBA 132 102-B 1445
3GBA 162 041- G 1459
66
88.2
65
1462
89.2
65
134
115 65
165 65
30
240 67
37
292 68
45
2.3 2.7 0.317
2.4 3.0 0.374
2.7 2.7 0.485
317 68
341 68
arrangements, voltage and frequency code (see ordering information page).
1/1 Starting current
T₁/T₁= Locked rotor torque
T/T Breakdown torque
3GBA 071 101-B 2705
3GBA 071 102-B 2680
3GBA 081 101-B 2820
3GBA 081 102-B 2805
3GBA 091 101- B 2890
73.2
78.1
79.5
82.2
Current
RIV General performance motore EN 02-2010 ABR IV Motore
Power
load factor N
cos A
IE1
1
Sound
Moment
of inertia
pressure
J= 1/4 GD² Weight level LA
kgm²
kg
dB
16
2.5 3.0 0.00199 22
Mater
11
11
14
10
1.9 2.0 0.00074
1.6 2.1 0.00088
11
2.0 2.8 0.00144 15
=
=
Efficiency values are given according to IEC 60034-2-1; 2007.
Please note that the values are not comparable without knowing the testing method.
ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.
58
56
60
60
63
45
45
45
Transcribed Image Text:General performance cast iron motors Technical data for totally enclosed squirrel cage three phase motors IP 55 - IC 411 - Insulation class F, temperature rise class B IE1 efficiency class according to IEC 60034-30; 2008 Efficiency IEC 60034-2-1; 2007 Full 3/4 1/2 Speed load load r/min 100% 75% 50% 400 V 50 Hz 69.2 Product code Torque TN T₁ T Output kW Nm Ty TN TN CENELEC-design 0.96 3.9 1.3 2.2 2.3 0.00039 73.5 73.7 0.80 77.3 79.3 0.85 77.9 0.81 79.1 Motor type 3000 r/min = 2-poles 0.37 M2BA 71 A 0.55 M2BA 71 B 0.75 M2BA 80 A M2BA 80 B M2BA 90 S M2BA 90 L M2BA 100 L M2BA 112 M 81.2 2.7 2.8 0.00101 u 1.1 1.5 2.2 82.5 3GBA 091 102-B 2875 83.4 63 2.3 2.4 0.00254 24 2.7 3.2 0.00445 32 3 3GBA 101 101- B 2910 65 4 3GBA 111 101- B 2880 37 67 61 75 5.5 7.5 11 15 18.5 22 30 68 73 118 73 132 73 140 73 167 75 213 75 239 75 296 75 338 75 37 45 1.27 4.3 1.95 2.4 2.49 0.00051 1.71 5.9 2.5 2.3 2.7 0.0008 81.2 0.82 2.4 5.7 3.7 80.3 0.81 3.2 7.2 4.9 84.5 83.5 0.84 4.5 6.6 7.3 83.2 83.4 81.4 0.83 6.2 7.0 9.8 84.9 86.2 85.9 0.89 7.6 7.5 13.2 2.4 2.6 0.00531 3GBA 131 101- B 2885 85.4 85.0 83.0 0.82 11.3 6.6 18.2 2.3 3.35 0.01029 3GBA 131 102-B 2890 86.5 86.3 84.3 0.81 15.4 7.6 24.7 2.7 3.5 0.01275 3GBA 161 041- G 2921 88.2 89.0 88.1 0.89 20.2 6.3 35.9 1.7 2.7 0.038 3GBA 161 042-G 2929 89.3 90.2 89.3 0.90 26.9 7.1 48.9 2.2 3.1 0.048 3GBA 161 043-G 2935 89.8 90.1 89.4 0.91 32.6 7.2 60.1 2.2 3.2 0.054 3GBA 181 041-G 2928 90.4 90.6 89.6 0.90 39 7.1 71.7 2.8 3.1 0.059 3GBA 201 041- G 2948 91.1 91.1 89.8 0.88 54 7.7 97.1 2.8 3.6 0.093 3GBA 201 042-G 2949 91.6 92.0 91.6 0.92 63.3 7.7 119 2.5 3.4 0.118 3GBA 221 041- G 2948 92.1 92.3 91.8 0.91 77.4 7.7 145 2.7 2.9 0.198 3GBA 251 041- G 2964 92.4 92.4 91.5 0.91 94.4 7.3 177 2.3 2.3 0.281 400 V 50 Hz CENELEC-design 0.81 0.65 3.5 1.74 0.83 0.88 4.0 4.0 2.5 73.8 70.0 0.73 1.45 5.0 3.7 77.0 77.0 73.7 0.72 1.95 5.0 5.0 78.4 79.6 78.4 0.79 2.5 4.8 7.4 1.9 2.3 0.0033 80.4 81.4 80.0 0.78 3.4 5.4 10.1 2.5 3.2 0.0044 83.2 84.3 83.5 0.80 4.7 5.4 14.7 2.1 2.8 0.00873 34 83.2 84.1 83.2 0.80 6.5 6.2 20.0 2.2 2.8 0.009 83.8 85.2 85.1 0.82 8.4 6.2 26.8 2.2 2.7 0.0106 39 87.8 87.8 85.9 0.76 11.8 6.0 35.9 1.8 2.7 0.02635 60 86.7 88.0 88.0 0.80 15.6 5.7 49.5 1.9 2.4 0.03282 70 89.0 88.4 0.81 22.2 6.5 71.9 2.3 2.6 0.068 120 3GBA 162 042-G 89.8 89.2 0.82 29.6 7.1 97.9 2.6 3.3 0.085 3GBA 182 041- G 1465 89.8 90.3 89.8 0.82 36.2 7.7 120 2.6 3.1 0.103 3GBA 182 042-G 1463 90.4 90.9 90.5 0.83 42.3 7.7 143 2.9 3.5 0.122 3GBA 202 041- G 1475 91.1 91.5 91.0 0.83 57.2 7.3 194 2.4 3.0 0.22 3GBA 222 041- G 1477 91.6 91.9 91.4 0.84 69.4 6.9 239 3GBA 222 042-G 1478 92.1 92.4 91.9 0.84 83.9 7.4 290 55 M2BA 250 SMA 3GBA 252 041- G 1478 92.4 92.7 92.2 0.85 101 7.4 355 The two bullets in the product code indicate choice of mounting 3GBA 072 101-B 3GBA 072 102-..B 1365 68.3 1380 72.4 74.5 70.8 69.7 74.5 74.6 3GBA 082 101-B 1415 M2BA 132 SA M2BA 132 SB M2BA 160 MLA M2BA 160 MLB M2BA 160 MLC M2BA 180 MLA M2BA 200 MLA M2BA 200 MLB M2BA 225 SMA 55 M2BA 250 SMA 1500 r/min 4-poles 0.25 M2BA 71 A 0.37 M2BA 71 B 0.55 M2BA 80 A 0.75 M2BA 80 B 1.1 M2BA 90 S M2BA 90 L M2BA 100 LA M2BA 100 LB M2BA 112 M M2BA 132 S M2BA 132 M M2BA 160 MLA M2BA 160 MLB M2BA 180 MLA M2BA 180 MLB M2BA 200 MLA M2BA 225 SMA M2BA 225 SMB 1.9 2.6 0.00198 16 50 22 50 1.5 25 50 3GBA 082 102-B 1410 3GBA 092 101-B 1410 3GBA 092 102-B 1410 3GBA 102 101-B 1425 3GBA 102 102-B 1430 3GBA 112 101-B 1420 64 2.2 3 35 67 60 66 4 5.5 7.5 11 15 18.5 22 3GBA 132 101-B 1460 3GBA 132 102-B 1445 3GBA 162 041- G 1459 66 88.2 65 1462 89.2 65 134 115 65 165 65 30 240 67 37 292 68 45 2.3 2.7 0.317 2.4 3.0 0.374 2.7 2.7 0.485 317 68 341 68 arrangements, voltage and frequency code (see ordering information page). 1/1 Starting current T₁/T₁= Locked rotor torque T/T Breakdown torque 3GBA 071 101-B 2705 3GBA 071 102-B 2680 3GBA 081 101-B 2820 3GBA 081 102-B 2805 3GBA 091 101- B 2890 73.2 78.1 79.5 82.2 Current RIV General performance motore EN 02-2010 ABR IV Motore Power load factor N cos A IE1 1 Sound Moment of inertia pressure J= 1/4 GD² Weight level LA kgm² kg dB 16 2.5 3.0 0.00199 22 Mater 11 11 14 10 1.9 2.0 0.00074 1.6 2.1 0.00088 11 2.0 2.8 0.00144 15 = = Efficiency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring. 58 56 60 60 63 45 45 45
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
DC Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,